14.2.5
ORP Alarm - High Alert
The high alert alarm sets an alarm to deactivate the
controller in the event of an ORP reading that is out of
high range. This could be an indication of a mechanical
malfunction in the feeding system.
From the CHEMLINK ORP setup screen, highlight the
HI ALERT values. Use the UP and DOWN arrows to
adjust the high alert values. Touch SAVE when finished.
ChemLink
ChemLink 1 ORP
Feeder
Feed TM
Delay OT
Set Point
High Alert
Low Alert
Page
Page
Orp
Up
Down
Home
Menu OneTouch
Help
Default
Range
14.2.6
ORP Alarm - Low Alert
The low alert alarm sets an alarm to deactivate the
controller in the event of an ORP reading that is out of
low range. This could be an indication of a mechanical
malfunction in the feeding system.
From the CHEMLINK ORP setup screen, highlight the
LOW ALERT values. Use the UP and DOWN arrows to
adjust the low alert values. Touch SAVE when finished.
ChemLink
ChemLink 1 ORP
Feeder
LIQUID
Feed TM
15 SEC
Delay OT
45 Min
Set Point
7.0
High Alert
Low Alert
Page
Page
Orp
pH
Up
Down
Home
Menu OneTouch
Help
Default
Range
AquaLink
Thu January 1, 2009 3:03 PM
Status
LIQUID
15 SEC
45 Min
Adjust
7.0
8.0
6.0
pH
Save
Back
Status
Photos
Power
950
350 to 950
Thu January 1, 2009 3:03 PM
Status
Adjust
8.0
6.0
Save
Back
Status
Photos
Power
100
100 to 650
®
Touch™ Owner's Manual
14.2.7
Wait or Stop pH
From the CHEMLINK ORP setup screen, highlight
the WAIT PH/STOP PH entry. Use the UP and DOWN
arrows to adjust the wait/stop pH entry. Touch SAVE
when finished.
ChemLink
ChemLink 1 ORP
Wait pH
Stop pH
Next Clean
Page
Page
Up
Down
Home
Menu OneTouch
Wait for pH:
YES= ORP will not feed at the same time as pH.
NO= ORP will feed regardless of when pH feeds.
Default= YES
Stop for pH:
YES= ORP will not feed if the pH is out of range.
NO= ORP will feed regardless of pH.
Default= YES
Thu January 1, 2009 3:03 PM
Status
NO
YES
Dec 22
Adjust
Orp
pH
Save
Help
Back
Status
Photos
Page 57