Section 12. Variable Speed Pump Setup; To Select The Pump/Model - Jandy AquaLink Touch Owner's Manual

Wired/wireless controller
Hide thumbs Also See for AquaLink Touch:
Table of Contents

Advertisement

Section 12. Variable Speed Pump
Setup
This equipment may not be part of your system.
NOTE
Please check with your installer.
A VARIABLE SPEED PUMP can be programmed to
run at any one of its eight (8) speeds.
Power to the variable speed pump is switched on/off
by a relay, so to program the pump you need to set a
program time for the relay, and for any speeds that you
wish to run during the pump's on cycle.
In the example shown below the variable speed pump
is used for pool filtration, so it will be powered from
the FILTER PUMP relay. Therefore, to program the
variable speed pump you must first set a program time
for the FILTER PUMP relay, then you need to program
the desired pump speeds to turn on/off during the
FILTER PUMP cycle.
If you do not program any speeds to run during the
filtration cycle, then by default the variable speed pump
will run at the POOL speed setting during its filtration
cycle.
Example:
1.
The total length of the fi ltration cycle is to be from
8am to 5pm. So program the FILTER PUMP to turn
on at 8am and to turn off at 5pm.
2.
To run the variable speed pump at the SPEED3
setting from 8am to 1pm, select VSP SPD1 PGM,
then select SPEED3, program it to turn on at 8am
and off at 1pm.
3.
To run the variable speed pump at the SPEED4
setting from 1pm to 5pm, select VSP SPD1 PGM,
then select SPEED4, program it to turn on at 1pm
and off at 5pm.
ON
FILTER PUMP
8AM
SPEED3
8AM
SPEED4
1PM
AquaLink
®
OFF
DESCRIPTION
5PM
Total duration of
filtration cycle
1PM
Pump runs at the
SPEED3 setting
5PM
Pump runs at the
SPEED4 setting
Touch™ Owner's Manual
The VAR SPEED PUMP menu is used to select the
variable speed pump type (Jandy ePump™, Pentair
IntelliFlo
VF, Pentair IntelliFlo VS, or Pentair
®
IntelliPro VS) and to select the various pump settings.
To interface the IntelliPro VS, select IntelliFlo VS.
12.1

To Select the Pump/Model

MENU > SYSTEM SETUP > VSP SETUP
From the SYSTEM SETUP screen, touch the VSP
SETUP button to display the VSP SETUP screen.
From the VSP SETUP screen, touch the PUMP/
MODEL button to display the SELECT VSP screen.
Touching the RESTORE SPD DEFAULTS button will
set the pump speeds, prime speeds and prime duration
to their factory default settings.
VSP Setup
Pump/Model
Application
1
Jandy ePump
Filtration
2 Pentair VS
Aux Pump
3 Pentair VF
Not Installed
4 VSP AC
Not Installed
Home
Menu OneTouch
In the PUMP MODEL list, select the variable speed
pump type and touch the SELECT button to save it.
Select VSP
Home
Menu OneTouch
Trademarks used herein are the property of their respective owners.
Page 47
Thu January 1, 2009 3:03 PM
Priming
Priming
Min
Max
Speed
Duration
400
RPM 3450 RPM
2500
900
RPM 3000 RPM
2500
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Restore Spd
Save
Defaults
Help
Back
Status
Photos
Thu January 1, 2009 3:03 PM
Pump Model
Jandy ePump
Pentair VS
Pentair VF
VSP AC
Select
Help
Back
Status
Photos
®
:05
:05
N/A
N/A
Speed
Setup
Power
Power

Advertisement

Table of Contents
loading

Table of Contents