Jandy AquaLink Touch Installation And Operation Manual

Jandy AquaLink Touch Installation And Operation Manual

Wired/wireless controller
Hide thumbs Also See for AquaLink Touch:

Advertisement

Installation and operation Data
Installation and
Operation Man u al
AquaLink
Wired/Wireless Controller
(For use with AquaLink
FOR INDOOR USE ONLY
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in
pool equipment by the jurisdiction in which the product will be installed where such state or local requirements
exist, the maintainer must be a professional with sufficient experience in pool equipment installation and
maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product,
read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices
and instructions may result in property damage, personal injury, or death. Improper installation and/or operation
will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury,
property damage, or death.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment to an electrical source on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Modifi cations made to this equipment, which are not authorized by the manufacturer, may void the user's authority
to operate this equipment.
Touch™
®
®
RS for Systems with Rev Q Firmware or later)
WARNING
ATTENTION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AquaLink Touch and is the answer not in the manual?

Questions and answers

Summary of Contents for Jandy AquaLink Touch

  • Page 1 Installation and operation Data Installation and Operation Man u al AquaLink Touch™ ® Wired/Wireless Controller (For use with AquaLink ® RS for Systems with Rev Q Firmware or later) FOR INDOOR USE ONLY WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist, the maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly.
  • Page 3: Table Of Contents

    Some of the features described in this Manual DO NOT apply to all AquaLink RS models. NOTE Changing the Frequency Channel ....12 Section 1. Important Safety Instructions ..4 Section 5. Using the Home Screen Menu ..13 Section 2. Overview of the AquaLink Touch Controller ........6 Home Screen ..........13 5.1.1 Title Bar .............13 System Overview ..........6...
  • Page 4: Section 1. Important Safety Instructions

    Page 4 AquaLink ® Touch™ and Operation Installation Manual Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS Lire la notice technique. All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: DANGER...
  • Page 5 Page 5 AquaLink Touch™ Installation and Operation Manual ® WARNING People with infectious diseases should not use a spa or hot tub. To avoid injury, exercise care when entering or exiting the spa or hot tub. Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.
  • Page 6: Section 2. Overview Of The Aqualink Touch Controller

    The AquaLink Touch controller can be used in addition to an existing AquaLink RS control system, however, the firmware, in the power center must be updated to revision Q or later. The AquaLink Touch controller is a Figure 1. Wall Flush-Mount AquaLink Touch Controller wall-mount or hand-held color touch screen that is pre- configured with a basic setup.
  • Page 7: Turning On The Aqualink Touch

    1. Turn off the screen. If the screen is dark, it will be easier to see the areas that are dirty or oily. To turn off the AquaLink Touch controller, touch the POWER button on the bottom navigation bar and a 2.
  • Page 8: Section 3. Wired Aqualink Touch Installation

    Installation The AC adapter and the power center NOTE The AquaLink Touch controller can be used in addition transformer will share the breaker panel to an already existing AquaLink RS control system, terminals. See Figure 7.
  • Page 9: Installation Of The Wired Aqualink Touch Ac Adapter Kit In The Low-Voltage Raceway

    PCB and bezel assembly as shown in 4-Pin Figure 8. Terminal Bar Wired Pull the white and black wires of the AC Adapter AquaLink Touch RS485 Cable into the high voltage area through the wire conduit. Mounting Bracket The AC adapter and the power center NOTE...
  • Page 10: Wired Flush-Mount Installation

    RS485 interface board and secure the AquaLink With the aid of the homeowner, fi nd the best Touch RS485 four (4) color cable to the red, 4-pin location for the AquaLink Touch controller. terminal bar. Reconnect the 4-pin terminal bar to the RS485 interface board.
  • Page 11: Wired Surface-Mount Installation

    (4) holes of the AquaLink Touch case. Hand tighten the screws. Anchor (2) Place the AquaLink Touch case on the wall and connect the wire harness of the front panel to the Surface Mount RS485 interface board.
  • Page 12: Section 4. Wireless Aqualink Touch Installation

    AquaL ink ® RS AquaLink Touch wireless control and the power center. The trans ceiv ers do not require line WARNING Only use the battery pack provided with the equipment.
  • Page 13: Section 5. Using The Home Screen Menu

    Returns the user to the previous screen. BACK and some user defined features. Displays information about the equipment. STATUS As shown in the figure below, the AquaLink Touch Displays the slideshow program and setup. PHOTOS menu screen displays the following layout: Turns off the controller.
  • Page 14: Section 6. Using The Menu Screen

    Page 14 AquaLink Touch™ and Operation Installation Manual ® Section 6. Using the Menu Screen First Step - Selecting the new device MENU > SCHEDULE > SCHEDULE DEVICES Menu Screen From the SCHEDULE screen, in the circuit schedule list, touch the ADD button to display the screen below. The MENU screen provides access to the main links to From the SCHEDULE DEVICES screen, in the program, set up, schedule, and customize your pool/spa...
  • Page 15: On/Off Times

    Page 15 AquaLink Touch™ Installation and Operation Manual ® 6.2.2 ON/OFF Times 6.3.1 Date MENU > SET DATE/TIME MENU > SCHEDULE From the MENU screen, touch the SET DATE/TIME From the SCHEDULE screen, in the circuit schedule button to display the SET DATE/TIME screen. list, touch the desired equipment to be scheduled.
  • Page 16: Customize Home

    Status displays an additional RF CHANNEL button. 6.5.1 Brightness The AquaLink Touch screen is designed to be lit so that you can use this controller in various lighting 6.4.1 Customize General, Aux and conditions. The brightness of the screen can be easily OneTouch™...
  • Page 17: Calibrate Aqualink Touch

    6.5.4 Address The AquaLink Touch controller is a touch-sensitive Up to four (4) AquaLink Touch controllers can be device and must be calibrated when the links are not connected to a system, but each device must be set to a responding to the touch, or when the touch-sensitive unique address.
  • Page 18: Aqualink Touch J-Box Led Operation

    SETUP button. to OFF and press the J-Box RESET switch. The screen displays “what would you like to set?”. 11. After a short time, the AquaLink Touch will return Select “RF Channel”. to the “waiting for connection…” screen, then to the home screen when connected successfully.
  • Page 19: Section 7. Troubleshooting

    Make sure the cradle is plugged into a wall socket. AquaLink Touch controller AquaLink Touch controller is Wired: Check the cabling to the AquaLink Touch backlight is on and the startup not communicating with the (all conductors).
  • Page 20 CONFORMS TO ANSI/UL STD. 60950-1 CERTIFIED TO CAN/CSA STD. C22.2 NO. 60950-1 Zodiac Pool Systems, Inc. 6000 Condor Drive • Moorpark, CA USA 93021 • 800.822.7933 • Fax 877.327.4103 © Zodiac Pool Systems, Inc. 1001...

Table of Contents