Section 14. ChemLink™ Setup
The ChemLink controller automatically monitors and
maintains both the sanitizer and the pH balance in
swimming pools, spas, or any circulating water system
that requires water chemistry management.
14.1

To Set Up the ChemLink

Check with the installer before making changes
NOTE
to the SYSTEM SETUP.
SYSTEM SETUP > SET CHEMLINK > CHEMLINK
From the SYSTEM SETUP screen, touch the SET
CHEMLINK button to display the CHEMLINK setup
screen.
As shown below, the CHEMLINK setup screen
provides links to set up the ORP/pH balances, ORP/
pH manual feeds, and level switch. Also, provides the
current values for the ORP and pH levels.
If only one chemLink is present in the system, the
CHEMLINK setup screen is displayed automatically.
ChemLink
ChemLink 1
ORP/pH Setup
ORP Manual Feed
pH Manual Feed
Level Switch
Home
Menu OneTouch
Help
If more than one chemlink is present, the screen will
display the links for additional chemlinks. To continue,
touch the button of the chemlink to be configured and
the CHEMLINK ORP/pH setup screen will appear.
ChemLink
ChemLink
ChemLink
Home
Menu OneTouch
Help
AquaLink
Thu January 1, 2009 3:03 PM
ORP 650
pH 7.5
Select
Back
Status
Photos
Power
Thu January 1, 2009 3:03 PM
1
2
Back
Status
Power
Photos
®
Touch™ Owner's Manual
14.2
To Confi gure the ORP Controller
From the CHEMLINK setup screen, highlight the ORP/
pH SETUP item and then touch SELECT to display the
CHEMLINK ORP/pH setup screen.
ChemLink
Home
Menu OneTouch
By default, the ORP configuration screen will appear as
shown below. Use this screen as follows:
▪ Touch ORP to confi gure the ORP controller (default).
▪ Touch pH to confi gure the pH controller.
▪ Use PAGE UP/DOWN to see additional items.
▪ Highlight item to be confi gured.
▪ Use the UP/DOWN arrows to adjust values.
▪ Touch SAVE when fi nished.
Make sure you touch the SAVE button when
NOTE
finished. Otherwise, your new setting will be
lost.
ChemLink
ChemLink 1 ORP
Feeder
Feed TM
Delay OT
Set Point
High Alert
Page
Page
Up
Down
Home
Menu OneTouch
Thu January 1, 2009 3:03 PM
ChemLink 1
ORP/pH Setup
ORP 650
pH 7.5
ORP Manual Feed
pH Manual Feed
Level Switch
Select
Help
Back
Status
Photos
Thu January 1, 2009 3:03 PM
Status
LIQUID
15 SEC
45 Min
Adjust
7.0
8.0
Orp
pH
Save
Help
Back
Status
Photos
Page 55