Default Preset Speed Labels (Rs Combo And Rs Only) - Jandy AquaLink Touch Owner's Manual

Wired/wireless controller
Hide thumbs Also See for AquaLink Touch:
Table of Contents

Advertisement

Page 50
From the GENERAL LABELS list, highlight the
desired device and touch the SAVE button. Use PAGE
UP /PAGE DOWN to scroll though the list. If you want
to assign a new label, touch the CUSTOM LABEL
button.
See Section 4.9.4, "Custom Label".
VSP Speed Label
Home
Menu OneTouch
Help
12.9
Default Preset Speed Labels (RS
Combo and RS only)
When a pump is configured for FILTRATION, the
speed presets will be labeled as shown in the table
below. The presets can be relabeled.
DEFAULT Labels when Pump is configured for
PRESET #
POOL/SPA
COMBO
1
POOL
2
SPA
3
SPEED3 or
CLEANER
(if dip S1-1 is on)
4
SPEED4 or
SPILLOVER
(if dip S1-3 is on)
5
POOL HEAT
6
SPA HEAT
7
SOLAR HEAT
(if dip S1-7 is off)
or HEATPUMP
(if dip S1-7 is on)
or SPEED7
8
INFLOOR
AquaLink
®
Touch™ Owner's Manual
Thu January 1, 2009 3:03 PM
Next
Back
Status
Photos
Power
FILTRATION
POOL/SPA
SPEED
ONLY
(RPM)
POOL
1725
SPEED2
2750
SPEED3 or
2750
CLEANER
(if dip S1-1 is
on)
SPEED4
2750
TEMP1
2250
TEMP2
2250
SOLAR HEAT
2750
(if dip S1-7
is on) or
HEATPUMP
(if dip S1-7 is
on) or SPEED7
INFLOOR
2750
Preset 1:
The default label for preset #1 is POOL. This label is
tied to the pool filtration mode. Anytime the pool pump
is supposed to turn on, this preset is selected.
Preset 2:
On combo systems the default label for preset #2
is SPA. This label is tied to the spa filtration mode,
anytime the spa pump is supposed to turn on, this preset
is selected.
Preset 3:
On combo systems, if dip switch S1-1 is ON, then the
default label for this preset is CLEANER. Anytime
the cleaner mode is turned on the pump will run at the
speed setting of this preset.
On a combo system, if dip switch S1-1 is OFF, then the
default label for this preset is SPEED3.
Preset 4:
If dip switch S1-3 is ON, then the default label for this
preset is SPILLOVER. Anytime the spillover mode is
turned on the pump will run at the speed setting of this
preset.
If dip switch S1-3 is OFF, then the default label for this
preset is SPEED4.
Preset 5:
On pool/spa combo systems the default label is POOL
HEAT. When the pool heater is enabled the pump will
run at this speed.
On pool/spa only systems the default label is TEMP1.
When the pump is running and the heater set point
TEMP1 is enabled, then the pump will run at this preset.
Preset 6:
On pool/spa combo systems the default label is SPA
HEAT. When the system is in the SPA mode and the
SPA HEATER is enabled then the pump will run at this
speed.
On pool/spa only systems the default label is TEMP2.
When the pump is running and the heater set point
TEMP2 is enabled, then the pump will run at this preset.

Advertisement

Table of Contents
loading

Table of Contents