14.3.3

pH Delay On Time

The delay on time sets the amount of time the controller
waits to dose the pool again.
From the CHEMLINK pH setup screen, highlight the
DELAY OT time. Use the UP and DOWN arrows to
change this time. Touch SAVE when finished.
ChemLink
ChemLink 1 pH
Feeder
Feed TM
Delay OT
Set Point
High Alert
Low Alert
Page
Page
Orp
Up
Down
Home
Menu OneTouch
Help
Type
ERO LP/MBV/ERO HP
Default
Do not use
Range
14.3.4

pH Setpoint

This setting specifies the level of sanitizer to be
maintained.
From the CHEMLINK pH setup screen, highlight the
SET POINT values. Use the UP and DOWN arrows to
adjust the SET POINT values.
ChemLink
ChemLink 1 pH
Feeder
Feed TM
Delay OT
Set Point
High Alert
Low Alert
Page
Page
Orp
Up
Down
Home
Menu OneTouch
Help
Default
Range
AquaLink
Thu January 1, 2009 3:03 PM
Status
LIQUID
15 SEC
45 Min
Adjust
7.0
8.0
8.0
pH
Save
Power
Back
Status
Photos
Liquid
30 Sec
.05 Sec to CONT
Thu January 1, 2009 3:03 PM
Status
LIQUID
15 SEC
45 Min
Adjust
7.0
8.0
8.0
pH
Save
Back
Status
Photos
Power
7.5
7.0 to 8.2
®
Touch™ Owner's Manual
14.3.5

pH Alarm - High Alert

The high alert alarm sets an alarm to deactivate the
controller in the event of a pH reading that is out of
high range. This could be an indication of a mechanical
malfunction in the feeding system.
From the CHEMLINK pH setup screen, highlight the
HI ALERT values. Use the UP and DOWN arrows to
change values. Touch SAVE when finished.
ChemLink
ChemLink 1 pH
Feeder
Feed TM
Delay OT
Set Point
High Alert
Low Alert
Page
Page
Up
Down
Home
Menu OneTouch
Default
Range
14.3.6

pH Alarm - Low Alert

The low alert alarm sets an alarm to deactivate the
controller in the event of a pH reading that is out of
low range. This could be an indication of a mechanical
malfunction in the feeding system.
From the CHEMLINK pH setup screen, highlight the
LOW ALERT setting. Use the UP and DOWN arrows to
change this setting. Touch SAVE when finished.
ChemLink
ChemLink 1 ORP
Feeder
Feed TM
Delay OT
Set Point
High Alert
Low Alert
Page
Page
Up
Down
Home
Menu OneTouch
Default
Range
Thu January 1, 2009 3:03 PM
Status
LIQUID
15 SEC
45 Min
Adjust
7.0
8.0
8.0
Orp
pH
Save
Help
Back
Status
Photos
8.4
7.5 to 8.4
Thu January 1, 2009 3:03 PM
Status
LIQUID
15 SEC
45 Min
Adjust
7.0
8.0
6.0
Orp
Save
pH
Help
Back
Status
Photos
6.8
6.8 to 7.4
Page 59