High Voltage Wiring; Low Voltage Wiring - Jandy Infinite WaterColors IWCP50W100 Installation And Operation Manual

Led light controller
Hide thumbs Also See for Infinite WaterColors IWCP50W100:
Table of Contents

Advertisement

ENGLISH
3.2

High Voltage Wiring

Risk of electric shock which can result in serious injury
or death: Before attempting to install or service, ensure
that all power to the circuit supplying power to the system
is disconnected or turned off at the circuit breaker. All wiring
must be done in accordance with the National Electrical
Code
( NEC(R) )
, NFPA70
®
®
In Canada, the Canadian Electrical Code (CEC), CSA C22.1,
must be followed. All applicable local installation codes and
regulations must be followed.
Wiring connections must be made exactly as shown in
the wiring diagram found on the inside of the Infinite
WaterColors LED Light Controller cover. The NEC and
CEC also require that pool equipment be bonded together as
part of the equipotential bonding grid. Zodiac Pool Systems
LLC provides a labeled bonding lug on the bottom of the
Light Controller to accommodate this requirement.
1.
Turn off power at the breaker panel.
2.
Remove the cover. The cover is held on by one
screw, see Figure 4(a).
3.
Remove a knockout from the bottom left side of
the Light Controller.
4.
Thread a conduit connector that is rated to
local code into the knockout hole on the Light
Controller, see Figure 4(b).
5.
Feed 120 VAC through the conduit and conduit
connector on the Light Controller, see Figure 4.
6.
Connect the green ground wire to the ground
terminal bar in the Light Controller,
see Figure 4(c).
7.
Use wire nuts to connect the line wires (black
to black) and neutral wires (white to white), see
Figure 4(d).
8.
Proceed to section 3.3 Low Voltage Wiring.
Page 6
WARNING
.
®
Jandy
Infinite WaterColors
LED Light Controller
®
a
Figure 4.
Connect High Voltage Wires
3.3

Low Voltage Wiring

1.
Remove a knockout from the bottom right side
of the Light Controller.
2.
Thread a conduit connector into the knockout
hole on the Light Controller, see Figure 5.
3.
Feed low voltage light cord through the conduit
and conduit connector on the Light Controller,
see Figure 5.
NOTE: It is recommended to add a junction box when
installing more than two lights.
4.
Use wire nuts to connect the low voltage light
wires, white wire connects to orange and black
wire connects to orange wire, see Figure 5.
If installing a niched light, connect the green
ground wire to the terminal bar in the controller
5.
Once power is restored, verify lights perform
the "rainbow sequence" (it could take up to two
minutes), this indicates the lights are powered
and communicating to the Light Controller.
NOTE: A blinking yellow light means no communication
between lights and the light controller.
|
Installation & Operation Manual
d
c
b

Advertisement

Table of Contents
loading

This manual is also suitable for:

Infinite watercolors iwc15w100

Table of Contents