USE AND MAINTENANCE MANUAL
Checking the hydraulic tubes
Avoid spilling the hydraulic fluid by using collection tanks,
and take precautions against the accidental loss and escape of
•
Control visually all hydraulic joints and tighten the junctions, if necessary.
•
Check all flexible hydraulic tubes; replace them, if necessary.
Check the performance
Use a chronometer for performing the following checks:
Perform the tests with the machine on a level surface, with the diesel/petrol engine on and
Safety speed
•
Select safety speed on the platform control panel.
•
Set the crawling tracks joysticks to maximum forward position.
•
Check that the machine covers a 10 m distance in more than 75 sec.
Lifting/lowering of the boom
•
Select the boom lifting function from the ground control panel and check that it takes about 36 sec.
to complete the lift.
•
Lower the boom and check that it takes about 36 sec.
Hydraulic oil is a pollutant
hydraulic fluid by using oil-absorbent products
the engine switched to "hare"
119
IM R13 T