USE AND MAINTENANCE MANUAL
Change the oil filter cartridge
The cartridge must be replaced when:
•
upon every oil replacement
•
in compliance with the schedule stipulated in the Table of Maintenance
•
when the error code 556 is displayed on the platform control panel display and all the machine
operations have been slowed down
The first replacement of the cartridge must be carried out after the first 50 working hours i
Avoid spilling the hydraulic fluid by using collection tanks, and take precautions against
the accidental loss and escape of hydraulic fluid by using oil-absorbent products
The exhausted oil must be collected and may not be disposed of in the normal drain lines. Use
a specialised company authorised to dispose of or recycle industrial oils, under the control of
Grease the mechanisms
Thrust block:
•
3 greasers on the worm
•
2 greasers on the sides of the chassis to distribute the grease over the teeth
Stabilisers:
•
1 on the cylinder
•
1 on the pin
Housing:
•
All the cylinder pins (excluding the strain pivot of the moment control)
Hydraulic oil is a pollutant
the current laws in the individual countries