USE AND MAINTENANCE MANUAL
Maintenance of the electric motor
Periodically check:
•
engine functions for any vibrations or irregular noise
•
air inlet on the rotor cover for any obstructions
•
for dust, oil leakage or other undue grime on the motor
Temperature relay
The temperature relay fitted on the machine serves to protect the electric motor against any possible
overload.
Perform the following test to check a correct functioning of the relay.
1. Open the protection box of the temperature relay.
2. Start the electric motor up.
3. Press down the red STOP key on the relay.
4. Check if the motor switches off.
5. Reset the motor using the blue RESET key.
Check plates and labels
Check that all plates and labels are well visible and have not been removed.
109
IM R13 T