Battery Recharging; Battery Charges Characteristics; 220 V Line; Battery Charges Characteristics; 110 V Line (Optional) - IMER IM R13 T Use And Maintenance Manual

Mobile elevating work platform
Table of Contents

Advertisement

USE AND MAINTENANCE MANUAL
The following pictogram on the display unit on the platform control panel will appear, in
+ _
addition to indicating the fault of the alternator (lit up steadily); it indicates the status of the
starter battery:
Flashing: the starter battery is below the warning level and must promptly be recharged.
To have it recharged the machine needs to be connected to the 220 V (or 110 V) mains and the circuit
breaker on the electric pump battery charger needs to be switched on.
The battery charger will switch on a green warning light while it is charging the battery and a red warning
light when charging is complete.

Battery charges characteristics; 220 V line

Battery charger 12 V 12 A
Power supply 185/265 V – 47/62 Hz
Operating temperature from -10°C to +40°C
Charging curve IUoU
Protection against output short circuit
Protection against polarity reversal
Weight: 1.3 Kg
Battery charges characteristics; 110 V line
(optional)
Battery charger 12 V 12 A
Power supply 85/264V – 50/60Hz
Operating temperature from -10°C to +45°C
Charging curve IUoU
Protection against output short circuit
Protection against polarity reversal
Weight: 1.5 Kg

Battery recharging

100
IM R13 T

Advertisement

Table of Contents
loading