Operation
Information
6.2.2.
Actuator operation from remote
30
SAEx 07.2
SAEx 16.2 / SAREx 07.2
Figure 24: Local controls
[1]
Push button for operation command in direction OPEN
[2]
Push button STOP
[3]
Push button for operation command in direction CLOSE
[4]
Push button RESET
[5]
Selector switch
Hot surfaces, e.g. possibly caused by high ambient temperatures or strong
direct sunlight!
Danger of burns
Check surface temperature and wear protective gloves, if required.
Set selector switch [5] to position Local control (LOCAL).
The actuator can now be operated using the push buttons [1
-
Run actuator in direction OPEN: Press push button [1]
-
Stop actuator: Press push button STOP [2].
-
Run actuator in direction CLOSE: Press push button [3]
OPEN - CLOSE operation commands can be given either in push-to-run or in self-
retaining operation mode. In self-retaining mode, the actuator runs to the defined
end position after pressing the button, unless another command has been received
beforehand. For further information, please refer to Manual (Operation and setting).
Set selector switch to position Remote control (REMOTE).
Now, it is possible to operate the actuator via remote control, via operation
commands (OPEN, STOP, CLOSE) or analogue setpoints (e.g. 0
SAREx 16.2 Control unit: electronic (MWG)
ACExC 01.2 Non-Intrusive
.
.
3].
20 mA).