Mechanical Position Indicator/Running Indication - AUMA SAEx 07.2 Operation Instructions Manual

Multi-turn actuators with actuator controls aumatic acexc 01.2 non-intrusive
Hide thumbs Also See for SAEx 07.2:
Table of Contents

Advertisement

Indications
7.3.

Mechanical position indicator/running indication

42
SAEx 07.2
SAEx 16.2 / SAREx 07.2
Figure 50: Maintenance required
For further information, please also refer to <Corrective action>.
Failure (S0011)
The S0011 indication shows the causes of the failure indication according to NAMUR
recommendation NE 107.
If such an indication has occurred, the display shows S0011:
the number of indications occurred
a blinking circle with a cross after approx. 3 seconds
Figure 51: Failure
For further information, please also refer to <Corrective action>.
— Option —
Mechanical position indicator:
Continuously indicates the valve position
(For complete travel from OPEN to CLOSED or vice versa, the indicator disc
[2] rotates by approximately 180° to 230°.)
Indicates whether the actuator is running (running indication)
Indicates that the end positions are reached (via indicator mark [3])
Figure 52: Mechanical position indicator
[1]
Cover
[2]
Indicator disc
[3]
Mark
[4]
Symbol for position OPEN
[5]
Symbol for position CLOSED
SAREx 16.2 Control unit: electronic (MWG)
ACExC 01.2 Non-Intrusive

Advertisement

Table of Contents
loading

This manual is also suitable for:

Saex 16.2Sarex 07.2Sarex 16.2

Table of Contents