Accessories For Assembly; Stem Protection Tube For Rising Valve Stem; Mounting Positions Of Local Controls - AUMA SAEx 07.2 Operation Instructions Manual

Multi-turn actuators with actuator controls aumatic acexc 01.2 non-intrusive
Hide thumbs Also See for SAEx 07.2:
Table of Contents

Advertisement

SAEx 07.2
SAEx 16.2 / SAREx 07.2
ACExC 01.2 Non-Intrusive
4.4.

Accessories for assembly

4.4.1.

Stem protection tube for rising valve stem

4.5.

Mounting positions of local controls

SAREx 16.2 Control unit: electronic (MWG)
— Option —
Figure 10: Assembly of the stem protection tube
[1]
Cap for stem protection tube
[2]
Stem protection tube
[3]
Sealing ring
1.
Seal thread with hemp, Teflon tape, or thread sealing material.
2.
Screw stem protection tube [2] into thread and tighten it firmly.
3.
Push down the sealing ring [3] onto the housing.
4.
Check whether cap for stem protection tube [1] is available and in perfect con-
dition.
The mounting position of the local controls is selected according to the order. If, after
mounting the actuator to the valve or the gearbox on site, the local controls are in
an unfavourable position, the mounting position can be changed at a later date. Four
mounting positions are possible.
Figure 11: Mounting positions A and B
Assembly
17

Advertisement

Table of Contents