NOTICE
Damage caused by excessively high blow-out pressure
If the blow-out pressure used exceeds 6 bar, the piping and the heat sink can become
damaged.
● Do not exceed the blowout pressure of 6 bar. Avoid pressure surges.
4.5.2

Storing a device

If you are not going to commission the device immediately after delivery, ensure that it is stored
correctly.
Preconditions and preparations
● Store goods only in undamaged packaging. Unpack the goods if the packaging is damaged.
● Repair any damage to the packaging before putting the equipment into storage insofar as
General instructions for storage
Wherever possible, store the device in a storage room. The place of storage must satisfy the
following general conditions:
● Select a sufficiently sized dry and horizontal place of storage that is above flood level and
● The place of storage must be well ventilated as well as free of dust and frost.
● Protect the device against shocks and humidity.
SINAMICS SM150 6SL3815-7NP41-0AA1
Operating Instructions Rev.201910281301 EXAMPLE
Correctly store the goods corresponding to the type of goods.
this is necessary to ensure proper storage conditions.
free of vibration (v
≤ 0.2 mm/s).
eff
– Provide protection against extreme weather conditions.
– Optimum temperatures are between 10° C (50° F) to 50° C (120° F).
– Room temperature should be approx. 10 °C (14 °F) above the outside temperature.
– The temperature may not fall below ‑20 °C (-4 °F).
– For lower temperatures, agree on suitable measures together with Siemens.
– Relative humidity should be less than 60%.
– The floor of the place of storage must be sufficiently strong. Do not exceed maximum
permissible floor load levels or storage compartment load levels.
– The ambient air must not contain any harmful gases.
Preparations for use