MAINTENANCE
MUX20JP021602
may behave as a projectile. The electrolyte inside the cell may cause very serious
irritation to the respiratory tract, eyes and skin. In addition, venting may cause
the emission of highly corrosive vapours in the work environment. In this case,
all protective equipment suited to  limit exposure  to  toxic  fumes  must be  avai‐
lable.
MINIMUM EQUIPMENT REQUIRED:
• Class D fire extinguisher
• Eye protection or face shield
• Respirator with filter for hydrochloric acid and sulphur dioxide
• Neoprene gloves
• Acid‐resistant lab coats
• Baking soda, calcium oxide or acid absorbent in kit form
• Vermiculite
• Plastic bags
PROCEDURE:
In the event of electrolyte release from the cells, proceed as follows:
• Evacuate the people exposed to fumes from the area.
• Air the environment until the complete removal of the cell and until the cha‐
racteristic pungent odour has disappeared.
• If the cell is too hot, allow it to cool to ambient temperature before handling it.
• Wear safety equipment: coat, gloves, mask and filters, and move the cell to a
well‐ventilated area.
• Place every cell in a sealable plastic bag and remove the excess air, then seal
the bag.
• Place a cup of vermiculite in a second bag, place the first bag in the second and
seal it.
• Place everything in a third bag with some soda and seal the bag.
• Absorb and collect the leaked electrolyte with absorbent material or soda.
• Place the absorbent material in a bag and seal it.
• Clean the area with plenty of water.
• Dispose of the hazardous material in accordance with the local legislation in
force.
FIRST AID IN THE EVENT OF CONTACT WITH THE ELECTROLYTE:
178