Installing the mounting frame
1
2
3
4
4.5
Positioning the boiler
15/06/12 - 300022160-001-01
The boiler is delivered with a mounting template.
1. Position the mounting template to the wall with adhesive tape.
CAUTION
Using a spirit level, check that the mounting axis is
perfectly horizontal.
2. Drill 3 holes with a Ø of 10 mm.
Additional holes are provided in case one or other of the
standard locating holes prevents the correct location of the
plugs.
3. Put the plugs in place.
4. Secure the mounting frame to the wall using the 3 hexagonal
headed screws provided for this purpose.
T001869-A
1. Remove the protective caps from all of the hydraulic inlets and
outlets on the boiler.
T001870-A
4. Installation