4. Installation
Settings to be made for this type of installation
Parameters
Access
INSTALLATION Installer level
#SYSTEM menu
Installer level
CIRC. B:
#SYSTEM menu
If I.TEL: is used
Installer level
#SYSTEM menu
I.TEL:
Installer level
MAX. CIRC. B
#SECONDARY LIMITS menu
46
Connect the swimming pool sensor.
Z
Plate heat exchanger.
E
Pool heating cut-off control
R
When the parameter I.TEL: is on 0/1 B, the
swimming pool is no longer heated when the
contact is open (factory setting), only the
antifreeze continues to be active.
The contact direction can still be adjusted by the
parameter CT.TEL.
Connect the primary swimming pool pump.
T
Do not connect anything to the terminal block.
Y
Settings to be made
EXTENDED
SWIM.P.
0/1 B
Set the value of MAX.CIRC.B to
the temperature corresponding to
the needs of the exchanger
n Controlling the pool circuit
The control system can be used to manage a swimming pool circuit
in both cases:
Case 1: The control system regulates the primary circuit (boiler/
exchanger) and the secondary circuit (exchanger/pool).
4 Connect the primary circuit pump (boiler/exchanger) to the MB
outlet on the connection terminal block. The temperature
MAX.CIRC.B is then guaranteed during comfort periods on
programme B in summer and winter alike.
4 Connect the swimming pool sensor (package AD212) to the S
DEP B inlet on the connection terminal block.
4 Set the set point of the pool sensor using key C in the range 5 -
39°C.
Case 2: The pool has already a regulation system that is to be
kept. The control system only regulates the primary circuit
(boiler/exchanger).
4 Connect the primary circuit pump (boiler/exchanger) to the MB
outlet on the connection terminal block.
The temperature MAX.CIRC.B is then guaranteed during comfort
periods on programme B in summer and winter alike.
See chapter
¼ "Displaying the parameters in
extended mode", page 69
¼ "Setting the parameters
specific to the installation", page 70
¼ "Professional settings", page
81