12 • FlipTop Storage Center: QM-FTSC
becomes brittle. Insert the tinned connection into the Cresnet connector and
tighten the retaining screw. Repeat the procedure for the other three conductors.
NOTE: For additional information on video connections over CAT5, refer to
the latest version of the Crestron CAT5 Wiring Reference Guide (Doc. 6137)
which is available from the Downloads | Product Manuals section of the
Crestron website (www.crerstron.com).
NOTE: For larger networks (i.e., greater than 28 network devices), it may be
necessary to add a Cresnet Hub/Repeater (CNXHUB) to maintain signal quality
throughout the network. Also, for networks with lengthy cable runs or varying
types of network devices, it may be desirable to add a hub/repeater after only 20
network devices.

Identity Code

Every equipment and user interface within the network requires a unique
identity code (Net ID). These codes are two-digit hexadecimal numbers from 03
to FE. The Net ID of each unit must match an ID code specified in the SIMPL
Windows program. Refer to "Setting the Net ID in Device Settings" on page 26
for details of the SIMPL Windows procedure.
The Net ID of the QM-FTSC has been factory set to 04 for the input/output
section, and 73 for the keyboard section. The Net IDs of multiple QM-FTSCs in
the same system must be unique. Net IDs are changed from a personal computer
(PC) via the Crestron Viewport.
NOTE: For detailed information on establishing communication between the
PC and control system, refer to "Communication Settings" on page 34. If
communication cannot be established, refer to the "Troubleshooting
Communications" section in the respective Operations Guide for the control
system.
There are two different methods—Method A or Method B—for setting the Net
ID:
Method A (Cresnet address-settable ID), described as follows, applies to
devices in a Cresnet system with a 2-Series control system and requires that a
single unit be the only network device connected to the control system.
Method B (Touch Settable ID or TSID), which begins on page 13, applies to all
TSID-ready devices in a Cresnet system with 2-Series control system upgrade
file (CUZ) version 3.029 or later. TSID functionality makes it possible for the
control system to recognize a network device via its serial number, which is
stored in the device's memory. This method does not require that any devices be
disconnected from the network; Net IDs may be set with the entire Cresnet
system intact. This method requires the use of the Crestron Viewport version
3.35 or later.
Use the appropriate method to set the Net ID.
Method A (Cresnet address-settable ID)
1. Ensure that the device requiring a Net ID change is the only unit
connected to the control system.
2. Open the Crestron Viewport.
Crestron QM-FTSC
Operations & Installation Guide - DOC. 6269