Error Code List and Action

PLC
Error
operation
code
at error
occurrence
I/O configuration error [M8060(D8060)]
Head unconnected I/O device number
Example: When X020 is unconnected
Example:
Continues
1020
operation
1st to 3rd digits: Device number
4th digit: I/O type (1:Input X 0:Output Y)
Example: When D8060 stores "1020", inputs X020
Serial communication error [M8438(D8438)]
0000
-
No error
3801
Parity error, overrun error or framing error
3802
Communication character error
3803
Communication data sum check error
3804
Data format error
3805
Command error
3806
Monitoring timeout error
3807
Modem initialization error
3808
Simple N:N link parameter error
3809
N:N Network setting error
Continues
3812
Parallel link character error
operation
3813
Parallel link sum check error
3814
Parallel link format error
3820
Inverter communication error
3821
MODBUS communication error
3830
Memory access error
3840
Special adapter connection error
PLC hardware error [M8061(D8061)]
0000
-
No error
6101
Memory access error
6102
Operation circuit error
Stops
operation
6103
I/O bus error (while M8069 is ON)
6104
24V failure in function unit (while M8069 is ON)
6105
Watchdog timer error
6106
I/O table creation error (CPU error)
Contents of error
1 0 2 0
Value converted into BCD
Device number
1:Input X 0:Output Y
and later are unconnected.
5.1 FX3S/FX3G/FX3GC/FX3U/FX3UC PLCs
Action
Unconnected I/O relay numbers are programmed.
The PLC continues its operation.
Modify the program if necessary.
Ethernet communication, Inverter communication, computer link
and programming:
Confirm that parameters are set correctly in accordance with the
application.
Simple N:N link, parallel link, MODBUS communication, etc.:
Confirm that the program is set correctly in accordance with the
application.
Remote maintenance:
Confirm that the modem power is ON, and that AT commands are
set properly.
Confirm the wiring of communication cables.
When the memory cassette is used, check whether it is mounted
correctly.
If the problem persists or if the memory cassette is not used,
something may be malfunctioning inside the PLC.
Consult your local Mitsubishi Electric representative.
Check connection of the special adapter.
When the memory cassette is used, check whether it is mounted
correctly.
If the problem persists or if the memory cassette is not used,
something may be malfunctioning inside the PLC.
Consult your local Mitsubishi Electric representative.
Isolate the PLC and supply power to it using a different power supply.
If the ERROR(ERR) LED turns OFF, noise may be affecting the PLC.
Take the following measures.
-
Check the ground wiring, and reexamine the wiring route and
installation location.
-
Fit a noise filter onto the power supply line.
If the ERROR(ERR) LED does not turn OFF even after the above
actions are taken, consult your local Mitsubishi Electric
representative.
Verify that extension cables are correctly connected.
The sampling (scan) time exceeds the value stored in D8000.
Check the program.
24V DC power failure has occurred in a function unit when the power
is turned ON. (The 24V DC power is not supplied for 10 seconds or
more after the power is turned ON.)
I/O assignment to the CC-Link/LT (built in the FX
is disabled when the power is turned ON.
5 Errors
1
2
3
4
5
6
7
-32MT-LT/LT-2)
3UC
245

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-lMelsec-fFx3sFx3gFx3gcFx3u ... Show all

Table of Contents