Mitsubishi Electric MELSEC-Q Structured Programming Manual page 292

Hide thumbs Also See for MELSEC-Q:
Table of Contents

Advertisement

FXCPU Structured Programming Manual
[Device & Common]
2. On the "Special Function Block Settings" dialog box, set the initial values of the selected
special function block/unit.
On the "Special Function Block" tab, select the unit number and click the [Setting] button to
display the "Special Function Block Settings" dialog box.
The "Special Function Block " tab is available only in FX
Set item
"Unit No." tab
Unit Name
No.
Address
Comment
Value
Size/Type
Insert
Delete
Up
Down
Check the Identification Code
Before Initializing
Identification Code
*1.
Input the buffer memory addresses (BFM numbers) held in the connected special function block/unit.
*2.
To each buffer memory address (BFM number), set a value within the allowable range in the
connected special function block/unit.
*3.
Refer to the manual of the connected special function block/unit.
3. Click the [OK] button to finish the setting and close the "Special Module Initial Setting"
dialog box.
290
Contents of setting
Select the unit number of a special function block/unit to be set.
Set the name of a special function block/unit whose initial values will be set.
This column indicates the order of initial value setting in the selected unit
number.
Numbers 1 to 98 can be set.
Set the buffer memory address (BFM number) in a decimal value whose initial
value will be set.
This column is displayed when device comments are registered.
On the above screen, "Input mode of CH1 to CH4" is registered as the device
comment for "U0\G0 (unit No. 0, BFM #0)".
Set a value to be set as the initial value of the buffer memory address (BFM
number).
Set the data length and type of the set value in the "Size/Type" column.
Select the size and type of a value set to the buffer memory among the following
choices:
16-bit/DEC
32-bit/DEC
16-bit/HEX
32-bit/HEX
This button inserts a line in the currently selected position.
This button deletes the currently selected line.
This button moves the cursor to the upper line (transposes the upper line).
This button moves the cursor to the lower line (transposes the lower line).
Check this item to check the model code of the special function block/unit before
initialization.
Set the model code of the function block/unit.
6 Types and Setting of Parameters
6.6 Parameter setting by GX Works2
, FX
PLCs.
3U
3UC
Setting range
-
Up to 32 half-width
(or 16 full-width)
characters
-
*1
-
*2
-
-
-
-
-
-
*3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-lMelsec-fFx3sFx3gFx3gcFx3u ... Show all

Table of Contents