Mitsubishi Electric MELSEC-Q Structured Programming Manual page 143

Hide thumbs Also See for MELSEC-Q:
Table of Contents

Advertisement

FXCPU Structured Programming Manual
[Device & Common]
Number and name
Step ladder and annunciator
M 8040
Disables transfer between states.
Transfer disable
*1
Enables transfer from the initial state during automatic
[M]8041
operation.
Transfer start
[M]8042
Gives pulse output in response to start input.
Start pulse
*1
M 8043
Should be set to ON in the zero return mode end state.
Zero point return
complete
*1
Should be set to ON when the machine zero point is
M 8044
detected.
Zero point condition
M 8045
Disables reset of all outputs when the operation mode
All output reset disable
switches.
Remains ON while M8047 is ON and either one among S0
*2
[M]8046
STL state ON
to S899 and S1000 to S4095
*2
M 8047
Enables M8040 to D8047.
STL monitoring enable
*2
Remains ON while M8049 is ON and either one among
[M]8048
S900 to S999 is ON.
Annunciator ON
*1
M 8049
Enables D8049.
Annunciator enable
*1.
Cleared when the PLC mode switches from RUN to STOP.
*2.
Activated when the END instruction is executed.
*3.
S1000 to S4095 are available only in the FX
Interrupt disable
M 8050
(Input interrupt)
*4
I00
disable
M 8051
(Input interrupt)
*4
I10
disable
When a special M for disabling input interrupt or timer
M 8052
interrupt is ON
(Input interrupt)
Even if an input interrupt or timer interrupt occurs while
*4
I20
disable
acceptance of the corresponding interrupt is disabled,
M 8053
the interrupt program is not executed.
(Input interrupt)
For example, when the interrupt I00
*4
I30
disable
M8050 is ON (to disable the interrupt I00 ), the interrupt
program is not executed even within the interrupt
M 8054
enabled program area.
(Input interrupt)
When a special M for disabling input interrupt or timer
*4
I40
disable
interrupt is OFF
M 8055
a) When an input interrupt or timer interrupt occurs, it
(Input interrupt)
*4
I50
disable
b) The interrupt program is executed immediately if
M 8056
(Timer interrupt)
*4
I6
disable
M 8057
(Timer interrupt)
*4
I7
disable
M 8058
(Timer interrupt)
*4
I8
disable
M 8059
Counter interrupt
Disables interrupts I010 to I060.
*4
disable
*4.
Cleared when the PLC mode switches from RUN to STOP.
Operation and function
*3
is ON.
is given while
is accepted.
interrupts are enabled by the EI instruction.
If the DI instruction disables interrupts, execution of
the interrupt program is paused until the EI
instruction enables interrupts.
4 Operations of Special Devices (M8000 and later, D8000 and later)
4.1 Special Device List (M8000 and later, D8000 and later)
FX
FX
FX
3U
3UC
, FX
, FX
, FX
, or FX
3S
3G
3GC
3U
-
Applicable model
Corresponding
FX
FX
3G
3GC
3S
special device
-
-
-
-
-
-
M8047
D8040 to D8047
-
-
D8049
-
M8048
PLCs.
3UC
-
-
-
-
-
-
-
-
-
-
-
-
1
2
3
4
5
6
7
141