Technical Specification - Proceq ZRP 6030+ Instruction Manual

Retroreflectometer
Table of Contents

Advertisement

18 Technical specification

Observation angle:
Illumination angle:
Measuring area WxH):
Measuring sensor:
Measuring range:
Repeatability:
Reproducibility:
Measuring time:
Memory:
Memory size:
Memory capacity:
Touchscreen display:
External charger:
Accumulator:
Charging time:
Life cycle LED:
Operating temperature:
Storage temperature:
Material housing:
Dimensions (LxWxH):
Dimensions road studs:
Weight:
Standards:
based on EN 1463 : 0.30°
ASTM E1696 : 0.20°
based on EN 1463: 1°
ASTM E1696: 1°
130 mm x 30 mm (5.12" x 1.18")
adapted to V ()
0-2'000 mcd∙lx
-1
± 2%
± 5%
1 s
internal flash memory
1 GB
50'000 measurements
5.7" colour TFT (LCD), LED backlight, VGA resolution
100 - 240 V / 50 - 60 Hz, 50 VA, universal
Li-Ion-Mn, 14,4 V, 6,5 Ah
approx. 3 hours
approx. 500'000 measurements
- 10° C to + 50° C (14°F to 122°F), non condensing
- 20° C to + 60° C (-4°F to 140°F)
anodised aluminium
560 mm x 190 mm x 280 mm (22.05" x 7.48" x 11.02"
Carrying case: 725 mm x 250 mm x 440 mm
max. 140 mm x 160 mm x 280 mm ( 5.51" x 6.30" x 2.36"
8.6 kg (18.96 Ibs) / 9 kg (19.84 lbs) incl. remote control
17.6 kg (38.8 Ibs) with transportation carrying case
ASTM E1696
based on EN 1463-2
Page 47
)