4.2 Supply voltage and control inputs/outputs MP60

Four removable terminal plugs are provided for connection.
Warning
The MP60 module must be connected to an external voltage supply of
18-30 V
(24 V
DC
D Twist wires of the voltage supply and fit end sleeves for strands.
D Screw ends of conductors to terminal plug 1.
D Insert terminal plug in top socket.
D Switch on voltage supply.
Terminal plug 2
Terminal plug 3
Label
Analogue OUT
±10 V
±20 mA
4...20 mA
IN1
IN = Digital input
You will find more about inputs and outputs in Chapter 6, page 44.
CAUTION
Fig. 4.1: Pin assignment for terminal plugs
The 4 terminal plugs are coded, so they can be inserted in the 4 sockets with
no danger of a mix-up. The sockets are provided with coded lateral guides
and the terminal plugs with coded pins.
A0616-13.4 en
Connect voltage supply
).
nom.
MP60
IN3
IN4
IN2
OUT = Digital output
In the event of a power failure on the MP60 module, all
control outputs are set to 0 V.
Voltage supply
0V
24 V
SYN
L
H
Terminal plug 1
Terminal plug 4
Label
0 V
24 V
OUT4
OUT1
OUT2
OUT3
19