Toshiba TOSVERT VF-AS1 Instruction Manual page 80

The new generation high-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

Below is an example of 7-step speed operation with standard default setting.
Output

frequency [Hz]
0
ST-CC
F-CC
S1-CC
S2-CC
S3-CC
4)Setting the operation mode
An operation mode can be selected for each preset speed.
Operation mode setting
Title
Preset speed operation mode

selection
: Preset speed operation with no mode ・・・・・ Only frequency commands are governed by the preset
: Preset speed operation with mode ・・・・・・・・ The direction of rotation, the V/f control mode, the
If you selected "enabled" (=), the motor runs operation mode setting directions as below without
following terminal F, R.
Operation mode setting
Title
Preset speed
operation frequency
~
1~15 operation mode
For the settings marked with +, more than one function can be selected at the same time by entering the sum of
the numbers of the desired functions.
Ex.) (+) + (+) = 
By entering "", you can activate the reverse run function and the acceleration/deceleration switching signal 1
function at the same time.



Example of 7-step speed operation
Function
: Preset speed operation with no
mode
: Preset speed operation with
mode
speed command (1 to 15) entered.
acceleration and deceleration times and the torque limit
can be set individually for each preset speed command.
Function
: Forward run
+: Reverse run
+: Acceleration/deceleration switching
signal 1
+: Acceleration/deceleration switching
signal 2
+: V/f switching signal 1
+: V/f switching signal 2
+: Torque limit switching signal 1
+: Torque limit switching signal 2
E-19



Adjustment range
Adjustment range
E6581301
Time
[s]
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
5
OFF
Setting value
Setting value

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents