Toshiba TOSVERT VF-AS1 Instruction Manual page 238

The new generation high-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

[15] Functions for lift [1/2]
Communi
Title
cation
Function
No.
Light-load high-speed operation
0328
f328
selection
Light-load high-speed teaching
0329
f329
function
Automatic light-load high-speed
0330
f330
operation frequency
Light-load high-speed operation
0331
f331
switching lower limit frequency
Light-load high-speed operation
f332
0332
load waiting time
Light-load high-speed operation
f333
0333
load detection time
Light-load high-speed operation
f334
0334
heavy load detection time
Switching load torque during
f335
0335
power running
0336
Heavy-load torque during power running -250~250%
f336
Heavy-load torque during
f337
0337
constant power running
Switching load torque during
f338
0338
regenerative braking
Light-load high-speed load torque
0339
f339
monitor 1
Light-load high-speed load torque
0340
f340
monitor 2
0341
Braking mode selection
f341
0342
Torque bias input selection
f342
f343
0343
Panel torque bias
f344
0344
Panel torque gain
0345
Release time
f345
f346
0346
Creeping frequency
f347
0347
Creeping time
0348
Braking time teaching function
f348
Acceleration/deceleration
f349
0349
suspend function
*1: ⇒ For details refer to the Instruction Manual (xxxxxxxx) for this parameter. *2: Inverter with a model number ending with -WN: 60.0 -WP: 50.0
Adjustment range
0:Deselect
1:High-speed operation speed set automatically
(Power running at F command: Increase)
2:High-speed operation speed set automatically
(Power running at R command: Increase)
3:High-speed operation speed set with 
(Power running at F command: Increase)
4:High-speed operation speed set with 
(Power running at R command: Increase)
0:No teaching
1:Forward run/reverse run teaching
2:Forward run teaching
30.0~ Hz
30.0~ Hz
0.0~10.0 sec.
0.0~10.0 sec.
0.0~10.0 sec.
-250~250%
-250~250%
-250~250%
-
-
0:Deselect, 1:Forward winding up
2:Reverse winding up
3:Horizontal operation (counter weight)
0:Disabled, 1~8 (same as )
-250~250%
0~100%
0.00~2.50 sec.
~20.0 Hz
0.0~2.5 sec.
0:Deselect, 1:Teaching (0 after adjustment)
0:Deselect, 1:Parameter setting, 2:Terminal input
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Enabled
●/●
1/1
0
Disabled
●/●
0.1/0.01
*2
Disabled
●/●
0.1/0.01
40.0
Enabled
●/●
0.1/0.1
0.5
Enabled
●/●
0.1/0.1
1.0
Enabled
●/●
0.1/0.1
0.5
Enabled
●/●
1/0.01
50
Enabled
●/●
1/0.01
100
Enabled
●/●
1/0.01
50
Enabled
●/●
1/0.01
50
Enabled
●/●
1/0.01
-
-
●/●
1/0.01
-
-
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/0.01
0
Enabled
●/●
1/0.01
100
Enabled
●/●
0.01/0.01
0.05
Enabled
●/●
0.1/0.01
3.0
Enabled
●/●
0.01/0.01
0.10
Disabled
●/●
1/1
0
Enabled
●/●
1/1
0
Disabled
●/●
PM
V/f
Reference
Torque
control
control
-
*1
-
-
-
*1
-
*1
-
*1
-
*1
-
*1
-
*1
-
*1
-
*1
-
*1
-
*1
-
*1
-
*1
-
-
-
6. 17
-
-
-
6. 17
-
-
-
6. 17
●/●
6. 17
-
-
-
6. 17
-
-
-
6. 17
-
-
-
6. 17
-
-
-
6. 17
●/●
6. 18