2) Standard specifications (large capacity types)
Item
Voltage class
Applicable motor (kW)
Type
Form
Output capacity
(kVA) Note 1:
Output current
(A)
Output voltage
Overload
current rating
Dynamic braking
circuit
Dynamic braking
resistor
Voltage-frequency
Allowable
fluctuation
Protective method
Cooling method
Color
EMI filter
DC reactor
Item
Voltage class
Applicable motor (kW)
Type
Form
Output capacity
(kVA) Note 1:
Output current
(A)
Output voltage
Overload
current rating
Dynamic
braking circuit
Dynamic braking
resistor
Voltage-frequency
Allowable
fluctuation
Protective method
Cooling method
Color
EMI filter
DC reactor
Note 1: Capacity is calculated at 220V for the 200V models and at 440V for the 400V models.
Note 2: Inverters, 18.5kW or greater, do not have wiring port covers. They have large openings, but there is no space
12
to bend the external cables inside the unit. If they are fitted external to the cabinet, please use an optional
wiring port cover.
Note 3: ±10% when the inverter is used continuously (load of 100%).
Note 4: For 200V-55kW, 400V-90kW or larger model, be sure to install DC reactor (optional).
However, this is unnecessary for DC input specifications.
55
2550P
84
221
Three-phase 200V~230V (The maximum output voltage is equal to the input supply voltage.)
         Three-phase 200~240V-50/60Hz Note 3
Voltage + 10% - 15% Note 5:
90
110
132
4900PC
4110KPC
4132KPC
136
164
197
179
215
259
Three-phase 380V~480V (The maximum output voltage is equal to the input supply voltage.)
Built-in dynamic braking drive circuit
Voltage + 10% - 15% Note 3:
L-2
Specification
200V class
VFAS1-
150%-1 minute, 165%-2 sec.
Built-in dynamic braking drive circuit
An external braking resistor (optional)
Rating: Refer to 5.19.
Frequency ±5%
IP00 Open type (JEM1030) Note 2
Forced air-cooled
RAL7016
External filter (optional)
Attached DC reactor
Specification
400V class
160
200
VFAS1−
4160KPC
4200KPC
239
295
314
387
150%-1 minute, 165%-2 sec.
External dynamic braking circuit (optional)
An external braking resistor (optional)
Rating: Refer to 5.19.
Three-phase 380~480V-50/60Hz
Frequency ±5%
IP00 Open type (JEM1030)
Forced air-cooled
RAL7016
Built-in
Attached DC reactor
E6581301
75
2750P
109
288
220
280
4220KPC
4280KPC
325
419
427
550