[15] Functions for lift [2/2]
Communi
Title
cation
Function
No.
0350
Acceleration suspend frequency 0.0~ Hz
f350
0351
Acceleration suspend time
f351
f352
0352
Deceleration suspend frequency 0.0~ Hz
f353
0353
Deceleration suspend time
[16] Commercial/inverter switching function
Communi
Title
cation
Function
No.
Commercial power/inverter
f354
0354
switching output selection
Commercial power/inverter
0355
f355
switching frequency
Inverter-side switching waiting
0356
f356
time
Commercial power-side
0357
f357
switching waiting time
Commercial power switching
f358
0358
frequency holding time
*1: Default values vary depending on the capacity. ⇒ See the table of K-46.
*2: Inverter with a model number ending with -WN: 60.0 -WP: 50.0
[17] PID control [1/2]
Communi
Title
cation
Function
No.
0359
PID control switching
f359
PID control feedback control
f360
0360
signal selection
0361
Delay filter
f361
f362
0362
Proportional (P) gain
*1: ⇒ For details refer to the Instruction Manual (xxxxxxxx) for this parameter.
Adjustment range
0.0~10.0 sec.
0.0~10.0 sec.
Adjustment range
0:OFF
1:Automatic switching in the event of a trip
2:Commercial power switching frequency setting
3:Commercial power switching frequency setting +
automatic switching in the event of a trip
0~ Hz
0.10~10.00 sec.
0.40~10.00 sec.
0.10~10.00 sec.
Adjustment range
0:No PID control
1:Process type PID control (temp./pressure, etc.)
operation
2:Speed type PID control (potentiometer, etc.)
operation
3:Stop retaining P control
0:Deviation input (no feedback input)
1:VI/II
2:RR/S4
3:RX
4:A1
5:A2
6: PG feedback option
0.0~25.0
0.01~100.0
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
0.1/0.01
0.0
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Disabled
●/●
0.1/0.01
*2
Enabled
●/●
0.01/0.01
*1
Enabled
●/●
0.01/0.01
0.62
Enabled
●/●
0.01/0.01
2.00
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0.1
Enabled
●/●
0.01/0.01
0.10
Enabled
●/●
PM
V/f
Reference
Torque
control
control
●/●
6. 18
●/●
6. 18
●/●
6. 18
-
6. 18
PM
Torque
V/f
Reference
control
control
●/●
6. 19
●/●
6. 19
●/●
6. 19
●/●
6. 19
●/●
6. 19
PM
V/f
Reference
Torque
control
control
-
6. 21
-
6. 21
-
*1
-
6. 21