[24] Pattern operation [3/3]
Communi
Title
cation
Function
No.
Preset speed operation frequency
0570
f570
10 operation mode
Preset speed operation frequency
0571
f571
11 operation mode
Preset speed operation frequency
f572
0572
12 operation mode
Preset speed operation frequency
f573
0573
13 operation mode
Preset speed operation frequency
f574
0574
14 operation mode
Preset speed operation frequency
f575
0575
15 operation mode
[25] Protection functions [1/3]
Communi
Title
cation
Function
No.
f601
0601
Stall prevention level 1
Inverter trip record retention
0602
f602
selection
f603
0603
Emergency stop
Emergency DC braking control
f604
0604
time
Output phase failure detection
0605
f605
selection
f606
0606
OL reduction starting frequency
0607
Motor 150%-overload time limit
f607
Input phase failure detection
f608
0608
mode selection
Low current detection current
f609
0609
hysteresis width
0610
Low current trip selection
f610
f611
0611
Low current detection current
f612
0612
Low current detection time
Adjustment range
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Adjustment range
0~165%, 165%:Deactivated
0:Clear when power is turned off
1:Retain even after power is turned off
0:Coast stop
1:Deceleration stop
2:Emergency DC braking
3:Deceleration stop (deceleration 4)
0.0~20.0 sec.
0:Deselect
1:At starting (only one time after power is turned
on)
2:At starting (each time power is turned on)
3:During operation
4:At starting + during operation)
5:Output cut-off detection enabled
0.0~30.0Hz
10~2400 sec.
0:Deselect
1:Select
1~20%
0:No trip, 1:Trip
0~100%
0~255 sec.
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
150
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Disabled
●/●
0.1/0.1
1.0
Enabled
●/●
1/1
0
Disabled
●/●
0.1/0.01
6.0
Enabled
●/●
1/1
300
Enabled
●/●
1/1
1
Disabled
●/●
1/1
10
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
PM
V/f Constant Reference
Torque
control
control
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
PM
Torque
V/f Constant Reference
control
control
-
6. 33. 1
●/●
6. 33. 2
●/●
6. 33. 3
●/●
6. 33. 3
●/●
6. 33. 4
●/●
5. 14
●/●
5. 14
●/●
6. 33. 7
●/●
6. 33. 8
●/●
6. 33. 8
●/●
6. 33. 8
●/●
6. 33. 8

Hide quick links: