Toshiba TOSVERT VF-AS1 Instruction Manual page 197

The new generation high-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

Parameter setting
Positive
logic
76
78
80
82
84
86
88
90
92
94
96
98
100
102
104
106
108
110
112
114
116
7
118
120
122
124
126
128
130
132
134
136
138
140
142
Note 1: "ON" in positive logic
"OFF" in positive logic : Open collector output transistor or relay is turned off.
"ON" in negative logic : Open collector output transistor or relay is turned off.
"OFF" in negative logic : Open collector output transistor or relay is turned on.
Note 2: Alarm output check conditions are as follows.
(1) Undervoltage detected :To be checked during operation.
(2) Low current detected
(3) Overtorque detected
Sink logic/source logic
Sink logic and source logic (logic of input/output terminal) can be switched to each other.
⇒ For details, refer to Section 2.3.2.
Negative
Function
logic
77
Inverter healthy output
RS485
79
communication error
81
Error code output 1
83
Error code output 2
85
Error code output 3
87
Error code output 4
89
Error code output 5
91
Error code output 6
93
Specified data output 1
Specified data output
95
2
Specified data output
97
3
Specified data output
99
4
Specified data output
101
5
Specified data output
103
6
Specified data output
105
7
107
Light load output
109
Heavy load output
111
Positive torque limit
113
Negative torque limit
Output for external rush
115
suppression relay
117
Over travel
Completion of stop
119
positioning
121
L-STOP
Power failure
123
synchronized operation
125
Traverse in progress
Traverse deceleration in
127
progress
129
Part replacement alarm
131
Over-torque pre-alarm
Frequency command 1/
133
2 selection
Failure FL (Except
135
emergency stop)
137
My function output 1
139
My function output 2
141
My function output 3
143
My function output 4
: Open collector output transistor or relay is turned on.
: To be checked during operation command.
: To be checked always.
Operation output specifications (in case of positive logic)
ON and OFF are alternately output at intervals of 1 second.
ON:Communication error occurred.
OFF:Communication error is canceled (reset).
Output the error code in 6-bit.
Output the error code in 6-bit.
Output of the designated data in 7-bit.
ON:Load is equal to  ~  set values or less.
ON:Load is larger than  ~  set value.
ON:Positive torque is over the positive torque limit level.
ON:Negative torque is over the positive torque limit level.
ON:External rush suppression relay is actuated.
ON:Over running
ON:Stop positioning has been completed.
ON:Operation at the lower limit frequency is performed
continuously.
ON:Power failure synchronized operation is performed.
ON:Traverse operation is performed.
ON:Traverse deceleration operation is performed.
Alarm:The time of replacement of parts is approaching.
ON:Over-torque is detected.
ON:Frequency command selection 2 is selected.
ON:A trip other than emergency stop has occurred.
ON:MY function output 1 is ON.
ON:MY function output 2 is ON.
ON:MY function output 3 is ON.
ON:MY function output 4 is ON.
G-8