7.3.2 Setup by analog input signals (VI/II terminal)
Connect current signal (4 (0) to 20mAdc) or voltage signal (0 to 10Vdc) to the terminal II so that the inverter can be run
and stopped with external commands.
Title
Command mode selection
Frequency setting mode selection 1
FM terminal meter selection
FM terminal meter adjustment
Analog VI/VII voltage/current switching
Frequency priority selection
VI/II input point 1 setting
VI/II input point 1 frequency
VI/II input point 2 setting
VI/II input point 2 frequency
Analog input filter
*1: Inverter with a model number ending with -WN: 60.0 -WP: 50.0
MCCB
Power
supply
7
Function
~
~
~
: Voltage input
: Current input
,
~ %
~ Hz
~ %
~ Hz
(No filter)~
(Max. filter)
CHARGE
U/T1
R/L1
VF-AS1
V/T2
S/L2
W/T3
T/L3
RES
S1
S2
FLA
S3
FLB
FLC
ST
F
P24/PLC
R
OUT1
OUT2
FM
AM
NO
CC
CC
CCA RX
VI/II
RR/S4
PP
+
-
To apply a voltage through the VI/II terminal, the
setting of needs to be changed.
Adjustment
Default setting
range
(Terminal)
(RR/S4)
-
-
*1
■Run/stop setup
To control switching between forward run
Motor
(F) and reverse run (R), run and stop by
external commands.
IM
■ S etup of frequency setting signal and
running frequency characteristic
To set up frequency setting signal to be
input to the external signal (VI/II terminal)
and characteristic of running frequency.
Frequency characteristic is set up at the
two points of VI/II reference point 1
(f201)/frequency (f202), VI/II
reference point 2 (f203)/frequency
(aif2).
Connection and calibration of
■
frequency meter
Forward run
Connect a 1mAdc full-scale DC current
meter, 7.5Vdc full-scale DC voltmeter or
Reverse run
rectifier type AC voltmeter. For calibration
of the meter, refer to the Section 5.16.
Frequency
Hz
meter
Point 1
Operation
frequency
0% 20% 100%
(0 ~ 4 ~ 20mA) current input
(0 ~ 10V ) voltage input
*4(0)~20mAdc
or 0~10Vdc
Frequency setting signal
G-12
E6581301
Setup value
4 (0)~20mAdc
0~10Vdc
(Terminal)
(Terminal)
( VI/II )
( VI/II )
-
-
*1
*1
Point 2
%