Kohler 14RESA Manual page 40

Residential/commercial generator sets
Hide thumbs Also See for 14RESA:
Table of Contents

Advertisement

management and cannot be changed by the user.
These outputs will display the load management relay
status.
Refer to Installation Instruction Sheet TT-1584,
provided with the PIM, for information about the input
and output events.
RBUS Devices
Up to four RBUS modules can be connected to the
generator set. RBUS modules can include one Model
RXT transfer switch, one programmable interface
module (PIM), one automatic paralleling module (APM),
and one load management device (load control module
(LCM), load shed kit, or the RXT combined
interface/load management board). If two generators
are paralleled using the APM, the second generator is
also considered an RBUS device but does not reduce
the number of RBUS modules that can be used.
SiteTech Group
Identity
Engine Metering
Engine Speed Governor
Generator Metering
* Read Only = Not adjustable
[ Notes indicate applicability to genset model and accessories. N/A = Not applicable to these generator sets.
] See TT-1584 for more information about digital inputs and outputs.
w Load management device (LCM, load shed kit, or RXT with combined interface/ load management board)
40
Section 4 Controller
Parameter
Vendor
Product
Firmware Version
Engine Speed
Engine Target Speed
Engine Oil Pressure
Engine Coolant Temperature
Battery Voltage
Lube Oil Temperature
Genset Controller Temperature
Engine Low Oil Pressure Switch
Engine Compartment
Temperature
Engine Speed Adjustment
Engine Speed Gain Adjustment
Generator Rotation Actual
Generator Current Lead/Lag L1
Generator Current Lead/Lag L2
Generator Current Lead/Lag L3
Generator Current Total Lead/Lag
Generator Power Factor L1
Generator Power Factor L2
Generator Power Factor L3
Generator Total Power Factor
Note: An RXT transfer switch with the combined
interface/load management board counts as two
RBUS devices (unless load management is
disabled on the combined board).
Load Management Devices
A load management device can be a load control
module (LCM), a load shed kit installed in an RDT or
RXT transfer switch, or a combined interface/load
management board installed in an RXT transfer switch.
Only one load management device can be connected.
The load management device counts as one RBUS
device.
A relay module (GM92001-KP1-QS) is a power relay
designed for use with the load shed kit or the combined
interface/load management board. The relay module
does not act as an RBUS device. See TT-1646.
Adjustment
Range *
Units
Read Only
Read Only
Read Only
R/min
Read Only
R/min
Read Only
kPa
Read Only
Read Only
_C
V
Read Only
Read Only
_C
Read Only
_C
Read Only
Read Only
_C
0 -- 99
See Section 4.4.2.
35--65
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Default
Setting
Notes
[
Kohler
Company
RDC 2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
50
50
N/A
3-phase
N/A
N/A
N/A
N/A
N/A
3-phase
N/A
N/A
N/A
N/A
N/A
N/A
N/A
3-phase
N/A
N/A
TP-6805 8/15