Kohler 14RESA Manual page 144

Residential/commercial generator sets
Hide thumbs Also See for 14RESA:
Table of Contents

Advertisement

29. Reinstall the enclosure panels in reverse order of
removal.
See Figure 7-39 and refer to the
disassembly instructions, if necessary.
a. Install the rear (alternator end) housing panel.
b. Install the non-service side housing panel.
c. Install the left side panel.
d. Install the heat shield over the muffler.
e. Install the front panel.
f. Install the generator set housing service side
door.
g. Install the generator set housing roof.
30. Re-apply the 120VAC power supply to the
generator set by closing the upstream circuit
breaker.
31. Turn on the fuel supply. Press RUN to start the
generator set and check for leaks with the engine
running.
32. Press OFF to turn off the generator set. Then press
AUTO if an automatic transfer switch or remote
start/stop switch is used.
33. Lower and secure the roof.
144
Section 7 Disassembly/Reassembly
7
1
5
2
1. Roof
2. Right (service) side door
3. Front panel
4. Heat shield (inside, not shown)
5. Left side panel
6. Non-service side panel
7. Rear panel
Figure 7-39 Generator Set Enclosure, 20RESB and
20RESD
6
4
3
ADV8564
TP-6805 8/15