6. Remove the plug and two door screws.
Figure 7-12. Lift the service-side door up and off.
1
1. Screws, qty. 2
2. Right side door
Figure 7-12 Right Side Door
7. Remove the front panel. See Figure 7-13.
1
2
1. Screws, qty. 3 (outside)
2. Screws, qty. 1 (inside)
Figure 7-13 Front Panel Mounting Screw Locations
8. Unplug the carburetor heater (if equipped) from the
120VAC receptacle.
9. Unplug the battery charger from the 120VAC
receptacle.
10. Disconnect the generator set engine starting
battery, negative (--) lead first.
132
Section 7 Disassembly/Reassembly
See
2
1
11. Disconnect output leads or load circuit cables at the
field-connection terminal block.
12. Remove the heat shield over the silencer by
removing four screws. See Figure 7-14.
1. Remove silencer heat shield
2. Screws, qty. 4
Figure 7-14 Heat Shield Removal
13. From the inside of the enclosure, remove the
screws to remove the left side panel.
Figure 7-15.
1
2
1. Screws (inside)
2. Left side panel
Figure 7-15 Left Side Panel Removal
1
2
1
TP-6805 8/15