System Component or Procedure
Fuel
Flexible lines and connections
Main tank supply level (LP)
Fuel piping
Fuel regulator vent tubes, if equipped (20 kW models)
Lubrication
Oil level
Change oil, 14 kW
Change oil, 20 kW
Replace filter
Crankcase breather hose
Oil cooler, if equipped
Cooling
Air ducts, louvers
Exhaust System
Leakage
Insulation, fire hazards
Obstructions or combustible materials near exhaust outlet
DC Electrical System
Check battery charger operation, voltage and charge rate
Remove corrosion, clean and dry battery and rack
Check battery electrolyte level and specific gravity
Clean and tighten battery terminals and inspect boots
Tighten DC electrical connections
AC Electrical System
Tighten control and power wiring connections
Remote control system, if equipped
Visible wear or damage
Wire abrasions where subject to motion
Wire-cable insulation condition
Engine and Mounting
Visible wear or damage
Air cleaner service *
Spark plugs
Replace stepper motor coupling and bushing
Generator
Visible wear or damage
Exercise generator set
Brushes and collector ring
Measure and record resistance readings of windings with insula-
tion tester (Meggerr, with controller or rectifier and load leads
disconnected)
General Condition of Equipment
Evidence of vibration, leakage, deterioration, unusual or exces-
sive noise or temperature
Interior of sound enclosure
* Service more frequently under extremely dusty/dirty conditions.
[ Service more frequently in temperatures above 29_C (85_F).
Meggerr is a registered trademark of Biddle Instruments.
Figure 2-1 Service Schedule
TP-6805 8/15
Visually
See
Inspect
Section
2.10
2.2
2.2.2
2.2.4
2.2.4
2.2.4
2.2.5,
2.2.6
2.6
2.6
2.8
2.8
[
3Y or 500
2.5
2.4
2.7
6.5, 6.6
E
Each use
W
Weekly
M
Monthly
Q
Quarterly
Y
Yearly
Procedure
Check
Change
Q
R
W
Y
Y
8 or E
Y or 100
Y or 150
Y or 150
Y or 500
Y
Y
W
W
Y
W
M
Y
Y
Y
Y
Y
Y
Q
6 months
6 months
W
150
300
150
300
500
Q
Y or 300
W
W
Q
Number = hours of operation
R
Replace as necessary
Section 2 Scheduled Maintenance
Clean
Test
Y
Y or 150
Y
Y
M
W
Y or 300
3Y (D)
W
Q
21