CONTROL OVERVIEW
CHANNEL SETUP - OUTPUTS
1.
Name of Output A
Enter a name for Multifunction Output A (shown on Home
Screen).
2.
Function - Output A
Select a function for Multifunction Output A. Default
function of this output is Master.
3.
Name of Output B
Enter a name for Multifunction Output B (shown on Home
Screen).
4.
Function - Output B
Select a function for Multifunction Output B. Default
function of this output is Master.
22
1
2
3
4
OUTPUT DEFINITIONS
Definitions:
Not Used - always off.
Aux Power - always on.
Master - off in hold.
Run/Hold Only - on in Run - unaffected by sections.
Relief - on in hold.
Fixed Flow (Fixed Flow Trigger) - on when the flow
per minute reaches a specified fixed total flow rate.
Proportional Flow (Proportional Flow Trigger) - on
when the flow per minute reaches a specified flow rate,
proportional to active sections.
Flush - on when Hold is detected and remains on for a
specified time period.
ADDITIONAL PARAMETERS
Fixed Flow and Proportional Flow Outputs require a
Threshold value input. The data entry box will appear
when feature is chosen from the function list.
Flush Output requires value inputs for Flush Time and
Flush Delay. The data entry boxes will appear when
feature is chosen from the function list.
Flush Time - duration of flush cycle.
Flush Delay - adjusts a time delay from the RUN/
HOLD transition to the start of the flush cycle.
HYP1100 (04-08-21)