CONTROL OVERVIEW
CONFIGURATION A
1
2
3
4
5
6
7
8
1.
Speed Source
Select Speed Source for the system. Default is Remote –
for an ISOBUS speed signal. Select Local to use a speed
sensor connected directly to the 2520-0258 harness.
2.
Speed Cal
Speed calibration number for Local speed - automatically
defaulted to .189.
3.
Minimum Alarm Speed
Enables and adjusts a minimum speed threshold for the
audible alarm - this prevents unneeded warnings while
stopping and starting. This can be set to OFF (0) or from
0.1 to 99.9 mph (km/h). Affected alarms are Application
Rate Error and Minimum Flow.
4.
Area Units
Select preference for Area Units for calculations and
display. Default unit is Acres - other choices are 1000 sq.
ft., or Sq. Yards. Exercise caution when changing Area
Units, the controller software will not automatically re-
calculate rate of application, etc.
5.
MTSI Width Source
Choose "Enable" for injection applications. Default for
this setting is Disabled.
6.
Quick Start Time
Enables Quick Start Time feature (0=off). This sends
a timed simulated speed signal to the control system
to cause an instant transition from Hold to Run. The
duration range is from 0 (off) to 6 seconds.
7.
Quick Start Speed.
Assigns a speed value in MPH (km/h) for Quick Start
feature (see previous).
HYP1100 (04-08-21)
8.
Test Speed
Check this box to send a simulated speed signal to the
control system for system diagnostics while implement
is parked. (Speed value data entry is disabled until box is
checked.).