SYSTEM INTERFACE OPERATION
MAIN OPERATING SCREEN – VIRTUAL/UNIVERSAL TERMINAL
1
CONTROLS
1.
ProStop-E Valve Control: Pressing turns individual valves/sections on or off. The colored display beneath the buttons will
change color to indicate on/off status. On=Green, Off=Red.
2.
Manual Pump ON/OFF Control: Defaults to OFF (Red on startup). Operator must turn to ON. When in manual mode and Run /
Hold is in Hold, the pump will continue to run for agitation. If tank is running low or empty, the pump can be turned off with this
control.
3.
Application Rate Control: Allows the application target rate to be adjusted up or down with each actuation.
4.
Display Readouts: By touching any of these rectangular displays, a choice of alternate functions is shown as a menu. The user
can select from the menu and replace the display with the desired item.
12
2
3
4
HYP1100 (04-08-21)