PROSTOP-E ISOBUS MODULE SYSTEM
Rate and Individual Nozzle Control
INSTALLATION AND
OPERATIONS MANUAL
pentair.com

Advertisement

Table of Contents
loading

Summary of Contents for Pentair PROSTOP-E

  • Page 1 PROSTOP-E ISOBUS MODULE SYSTEM Rate and Individual Nozzle Control INSTALLATION AND OPERATIONS MANUAL pentair.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION ........................................PAGE Safety Infomation..................................... 3 Overview......................................4 Installation....................................... 6 Operation......................................11 Control Overview....................................13 ProStop-E Dual....................................28 Control Overview................................... 32 Troubleshooting..................................... 36 Rate Controller Default Settings..............................39 Wiring Diagrams..................................... 41 Warranty....................................... 45...
  • Page 3: Safety Infomation

    SAFETY INFORMATION The ProStop-E rate controller can be used to control and apply CALIFORNIA PROPOSITION 65 WARNING This product and hazardous chemicals. Exposure to hazardous chemicals can related accessories contain chemicals known to the State of result in illness, severe injury, or death. Hazardous chemicals...
  • Page 4: Overview

    OVERVIEW Pentair Hypro ProStop-E ISOBUS System is an electronic spray rate controller that provides individual spray nozzle control via The rate controller calculates flow based on real-time inputs Controller Area Network (CAN bus) messaging with individual of speed, how many valves/sections are on/off and for nozzle nozzle valves.
  • Page 5 2520-0240 - ProStop-E cable PK-4223N-B524VPSE ProStop-E nozzle body 2520-0241 - ProStop-E cable connects nozzles to the left connects nozzles to the right NOTE: For ProStop-E Single and Dual nozzle bodies, use 2520-0265 for daisy-chain connection between nozzle bodies. HYP1100 (04-08-21)
  • Page 6: Installation

    Nevertheless, it is recommended you follow all steps in sequence when installing the ProStop-E ISOBUS rate controller and system components. It is also highly recommended that the user navigates through all the interface screens prior to in-field use to ensure that settings are correct for the desired application.
  • Page 7 For example the cannode on the left in Fig. 6 controls, the leftmost Prostop-E valves on the boom, the cannode on the right controls the rightmost valves on the boom and the center cannode controls the Prostop-E valves in the center section of the boom.
  • Page 8 INSTALLATION 7” [177.8 mm] ø .230” [5.8 mm] 3.93” [99.82 mm] Figure 9: Rate Controller Mounting Dimensions (2850-0029) HYP1100 (04-08-21)
  • Page 9 INSTALLATION CANNODE AND PROSTOP-E WIRING Each cannode can support a total of 32 ProStop-E valves, 10. On the last ProStop-E, install a 2300-0067 cap to seal the which are split between two segments on each cannode. unused port. There are a maximum of 16 ProStop-E valves which can be on 11.
  • Page 10 INSTALLING PRESSURE SENSOR OPTION The pressure (2530-0209, figure 10) sensor should be installed in the main plumbing line as close to the ProStop-E valves as possible. The sensor requires a 1/4”-18 NPT fitting. Install the sensor in the main plumbing line.
  • Page 11: Operation

    Application System review in this manual prior to beginning Field” procedure to ensure that your valve settings, nozzle any operations. selection and desired speed range will allow the ProStop-E ISOBUS rate controller to provide the required application MANUAL OPERATION control. This procedure should be repeated for each new This mode sets and maintains a steady flow rate (GPM) not nozzle selection and/or application rate.
  • Page 12 MAIN OPERATING SCREEN – VIRTUAL/UNIVERSAL TERMINAL CONTROLS ProStop-E Valve Control: Pressing turns individual valves/sections on or off. The colored display beneath the buttons will change color to indicate on/off status. On=Green, Off=Red. Manual Pump ON/OFF Control: Defaults to OFF (Red on startup). Operator must turn to ON. When in manual mode and Run / Hold is in Hold, the pump will continue to run for agitation.
  • Page 13: Control Overview

    Master - off in hold. ALARMS • Run/Hold Only - on in Run - unaffected by sections. If a parameter on the ProStop-E ISOBUS rate control system • Relief - on in hold. significantly exceeds, or falls short of established limits, an •...
  • Page 14 Target Rate Section On/Off buttons This display shows the programmed Target Rate of the These are the controls for individual ProStop-E valves/ system. The target rate can be incrementally adjusted sections. The sections can be toggled on/off from either using Increase/Decrease on-screen keys. The setting for direction using the on/off buttons.
  • Page 15 This setting is located in Ch. 1 Setup/ Implement tab. Note: If more than one liquid system will be controlled with the ProStop-E ISOBUS rate controller, channel 2 can be enabled by checking the “Enable Channel” button in the CH2 Setup screen.
  • Page 16 CONTROL OVERVIEW TOTALS Ch. 2 Distance Counter This is the Totals screen for the ProStop-E ISOBUS rate Displays cumulative distance traveled in feet. controller. It can also be used as an operating screen, if 10. Ch. 2 Operating Time desired.
  • Page 17 CONTROL OVERVIEW CONFIGURATION A Test Speed Speed Source Check this box to send a simulated speed signal to the Select Speed Source for the system. Default is Remote – control system for system diagnostics while implement for an ISOBUS speed signal. Select Local to use a speed is parked.
  • Page 18 CONTROL OVERVIEW CONFIGURATION B Forward (+) / Backward (-) Implement Switch - Run=Switch Measure the forward or backward distance from the hitch Selects polarity for remote implement switch connection to the Task Controller Reference Point. - reverses circuit function. The default setting is closed, Right (+) / Left (-) meaning that the system will be in Hold when the circuit Measure the right or left distance from the hitch to the...
  • Page 19 CONTROL OVERVIEW CONFIGURATION C NOTE: these settings should not need to be modified. Configuration Name Configuration Load The feature will reload configuration and reset all parameters to factory defaults, including erasing all Totals data. Configuration Save Disabled - may be enabled in future version of software, allowing user to save customized configurations.
  • Page 20 CONTROL OVERVIEW CHANNEL SETUP OPERATIONS Note: Fields 2, 5, 6 on this screen may not be modified when connected to the Task Controller. Channel Name Enter the name of the product being applied by channel. This name can be entered from any of the Channel Setup pages.
  • Page 21 CONTROL OVERVIEW CHANNEL SETUP SYSTEM Flowmeter Units & Value Control Valve - PWM This defines the flow pulse units and calibrates the system Enables Pulse Width Modulation valve control. to the flowmeter factory setting. Enter the value from the Operating Frequency flowmeter on the machine in this field.
  • Page 22 CONTROL OVERVIEW CHANNEL SETUP - OUTPUTS OUTPUT DEFINITIONS Name of Output A Definitions: Enter a name for Multifunction Output A (shown on Home • Not Used - always off. Screen). • Aux Power - always on. Function - Output A •...
  • Page 23 CONTROL OVERVIEW CHANNEL SETUP - CONTROL Enable Hybrid Control Control Speed This will allow the system to automatically switch from This value optimizes valve response time to fine-tune flow based control to pressure based control when the the system. Control speed can be set to a value of -12 system is spraying from a small number of nozzles, which (slowest reacting) to +3 (fastest reacting).
  • Page 24 CONTROL OVERVIEW CHANNEL SETUP - ALARMS Rate Alarm Threshold Adjusts threshold value for the Rate Alarm - can be set from 10-30%. This value is the percentage of difference between the actual rate of application and the intended (target) rate. Default setting is 10%. Low Pressure Alarm Enables and adjusts value for Pressure Alarm - set value to notify operator when low level is reached.
  • Page 25 Setup. See screen detail on the next page. Check the boxes for LEFT and RIGHT to allow for the control of fence row nozzles from the UT screen. Enabling fence nozzles assigns the far left and far right ProStop-E valves as Fence HYP1100 (04-08-21)
  • Page 26 “1” nozzle to allow for individual nozzle control. Use the arrow at the bottom of the screen to review all assignments. If creating Virtual Sections, enter the desired number of ProStop-E nozzles that will be in each section. CANNODE CONFIGURATION The cannodes must be organized to match the machine layout.
  • Page 27 This selection describes the controlled implement task controller to send, and the ProStop-E ISOBUS rate activity to the ISOBUS network, which is typically “Crop controller to respond to control commands.
  • Page 28: Prostop-E Dual

    Auto, to A, to B, to A + B, then back to Auto. When in Auto, the nozzles will switch based off the parameters defined in ProStop-E Dual Setup. When A, B, or A+B is selected, that is the active nozzle(s).
  • Page 29 PROSTOP-E DUAL IMPLEMENT TAB Section Valve Type For the Dual Nozzle control, select “ProStop-E Dual”. When this section valve type is selected, the features for dual nozzles are unmasked. HYP1100 (04-08-21)
  • Page 30 PROSTOP-E DUAL OPERATION TAB Nozzle Number / 1 Nozzle @ 40 PSI These features are masked when ProStop-E Dual is selected as section valve type. ProStop-E Dual Setup This button appears when ProStop-E Dual is selected as section valve type. This button directs the user to the setup page for dual nozzles.
  • Page 31 PROSTOP-E DUAL CHANNEL SETUP - ISOBUS Nozzle Pair be manually entered by the user or by pressing the “Calculate This setting defines which pair of nozzles is being used. The user Switching Points” button. can store values for up to two pairs.
  • Page 32: Control Overview

    CONTROL OVERVIEW CHANNEL SETUP - OPERATION SAVE CHANGES, AND EXIT SET PWM LIMITS Press Run/Hold softkey to stop pump. This setup routine establishes low and high PWM duty cycle limits for a PWM controlled device. Press Confirm softkey to save changes and exit back to Channel Setup.
  • Page 33 CONTROL OVERVIEW CHANNEL SETUP - OPERATION FINE TUNE FLOWMETER Press Run/Hold softkey to stop flow. This procedure is used to verify and fine-tune the flow calibration by catch test. The catch test result is then compared with the system calculated volume, and the system is then adjusted to match actual flow.
  • Page 34 CONTROL OVERVIEW DIAGNOSTIC 1 This tab contains a variety of information that is specific to ProStop-E ISOBUS Rate Controller - Serial Number, Hours,etc ECU Instance: Leave this value at 0 unless there are multiple ECUs of the same Device Class and Device Function on the bus.
  • Page 35 CONTROL OVERVIEW DIAGNOSTIC 2 Diagnostic tab 2 shows the raw data that is processed by the ProStop-E ISOBUS Rate Controller It is displayed as a troubleshooting reference only. Home: Softkey - directly navigates to the Home screen. Configure: Softkey - directly navigates to the Configure screen.
  • Page 36: Troubleshooting

    Pentair-Hypro SprayIt app can be used as a diagnostic tool for (English or metric). verifiying communication with the cannode(s) and actuation of ProStop-E valves. The SprayIt app can also be used for SYSTEM OPERATION (CONTROL) IS SLUGGISH IN AUTOMATIC checking indivdual spray nozzle patternation or for flow MODE testing.
  • Page 37 If there is a response at that connector, the problem may be System plumbing is a critical factor in obtaining optimal in the cable between the two connectors (or the con nectors performance from your ProStop-E ISOBUS rate control themselves). system. The chart on the next page may help you determine what area of the plumbing is causing your problem.
  • Page 38 Range valve slightly and perform the performance. The system diagrams (See pages 9-10) show Pre-Field System Checkout again. optimal plumbing configurations for the ProStop-E ISOBUS rate controller. THROTTLE VALVE The throttle valve limits your high end to maximize servo PRESSURE DROPS performance.
  • Page 39: Rate Controller Default Settings

    Disabled Enable Section Control Enabled Enabled Hitch to Reference (In./mm) Forward/Backward Hitch to Reference (In./mm) Right/Left Hitch Type Unknown Unknown Configurations HYPRO PROSTOP-E HYPRO PROSTOP-E Settings / Configuration Lock Unlocked Unlocked Factory Configuration Locked Locked Channel 1 Channel 2 Operation...
  • Page 40 RATE CONTROLLER DEFAULT SETTINGS Channel 1 Channel 2 Implement English Metric English Metric Section Valve Type PROSTOP-E PROSTOP-E PROSTOP-E PROSTOP-E Nozzle Spacing (in or mm) Total Sections Section Configuration Section 1 # of Nozzles Section 2 # of Nozzles Section 3 # of Nozzles...
  • Page 41: Wiring Diagrams

    WIRING DIAGRAMS PART NUMBER 2520-0258 HYP1100 (04-08-21)
  • Page 42 WIRING DIAGRAMS PART NUMBER 2520-0250 PART NUMBER 2520-0251 HYP1100 (04-08-21)
  • Page 43 WIRING DIAGRAMS PART NUMBER 2520-0252 PART NUMBER 2520-0253 HYP1100 (04-08-21)
  • Page 44 WIRING DIAGRAMS PART NUMBER 2520-0237 HYP1100 (04-08-21)
  • Page 45: Warranty

    ISOBUS, a standardized protocol for electronic communication between implements, tractors and computers (ISO 11783). The installation of the ProStop-E system will vary depending on your equipment. Please take time to familiarize yourself with this manual and the actual components before beginning installation. Following the procedures described in this manual will help ensure proper performance and avoid problems or questions once you are in the field.
  • Page 46 For a detailed list of where Pentair trademarks are registered, please visit www.pentair.com/en/registrations.html. Pentair trademarks and logos are owned by Pentair plc.or its affiliates. Third party registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.