Replace a Boot Drive in the Verde 4U Master Node
5. While pressing the clip in toward the boot drive module, lift the
Make sure you press in on the clip when removing the boot drive. The clip can break
Caution
off easily and damage the motherboard socket.
6.
7. Locate the serial number on the back of the failed module. Compare the
8. Disconnect the power cable from the failed module.
9.
10. Connect the power cable to the replacement module. The connector is
11. Orient the module with the SATA connector facing down and the clip
12. Press the module down into the socket to secure it to the motherboard.
13.
October 2013
module off the motherboard.
If you are replacing boot drive 2, repeat Step 4 on page 11 and Step
remove boot drive 2.
module serial number to the number you recorded in Identify the
Failed Boot Drive on page
Figure 11 Disconnect the power cable from the failed drive.
Set the failed module aside for return to Spectra Logic (see Returns on
page
22).
keyed to only fit one way, do not force it.
facing toward the inside of the chassis.
The connector is keyed to only fit one way, do not force it.
If you replaced boot drive 2, repeat Step 11 and Step
drive 1.
Boot Drive Replacement—Spectra nTier Verde Array
6 and confirm the numbers match.
Replace a Boot Drive
5 to
Power
cable
12 to install boot
12