Congratulations on your purchase of ArcSystem products. ArcSystem is a family of overhead LED
products designed for installations where dimming, light quality, and ease of installation are
absolutely essential. With ArcSystem, you will experience perfectly smooth dimming from 100%
down to absolute zero. ArcSystem luminaires come in a variety of form factors, beam angles, and
color-temperature options, all with high-efficiency optics and an outstanding quality of light ideal for
any application.
ArcSystem products with ArcMesh can be controlled using wired DMX or the wireless ArcMesh
protocol. ArcSystem products without ArcMesh can be configured for RDM control. This manual
provides step by step instruction on the installation of ArcSystem Pro One-Cell luminaires, D1 and D2
Series Drivers, and full system integration. For information on installing ArcSystem Pro D4 Series
Drivers see the ArcSystem D4 Series Drivers Installation Guide at etcconnect.com/ArcSystem. For
information on ArcSystem Pro Multi-Cell luminaires, see the ArcSystem Pro Installation Manual and
the ArcSystem Pro Multi-Cell RDM Installation Guide at etcconnect.com/ArcSystem.
All ETC manuals are available for download free of charge at etcconnect.com.
Safety
ArcSystem products are intended for professional use only. Read the entire manual before using this
equipment.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including
the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Corporate Headquarters Middleton, WI, USA +1 608 831 4116 London, UK +44 (0)20 8896 1000
Holzkirchen, DE +49 (80 24) 47 00-0 Rome, IT +39 (06) 32 111 683 Hong Kong +852 2799 1220 Paris, FR +33 1 4243 3535
Web
© 2021 ETC Trademark and patent
Product information and specifications subject to change. ETC intends this document to be provided in its entirety.
7491M2110 Rev F Released 2021-01
Do not use outdoors.
Do not let power supply cords touch hot surfaces.
Do not mount near gas or electric heaters.
Equipment should be mounted in locations and at heights where it will not readily
be subjected to tampering by unauthorized personnel.
The use of accessory equipment not recommended by the manufacturer may cause
an unsafe condition.
Do not use this equipment for other than intended use.
etcconnect.com
Support
support.etcconnect.com
Contact
etcconnect.com/contactETC
info: etcconnect.com/ip

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ArcSystem Pro D1 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ETC ArcSystem Pro D1 Series

  • Page 1 Holzkirchen, DE +49 (80 24) 47 00-0 Rome, IT +39 (06) 32 111 683 Hong Kong +852 2799 1220 Paris, FR +33 1 4243 3535 etcconnect.com Support support.etcconnect.com Contact etcconnect.com/contactETC © 2021 ETC Trademark and patent info: etcconnect.com/ip Product information and specifications subject to change. ETC intends this document to be provided in its entirety. 7491M2110 Rev F Released 2021-01...
  • Page 2: System Overview

    5000 K, or Fade to Warm variants. ArcSystem Pro multi-cell luminaires are covered in the ArcSystem Pro Multi-Cell RDM Installation Guide and ArcSystem Pro Installation Manual . All ETC manuals are available for download free of charge at etcconnect.com. D1 & D2 Series Drivers...
  • Page 3 ETC Installation Guide D1 & D2 Series Drivers D1 Series, D2 Series, and D4 Series Drivers D1 Driver D1 HO Driver D2 Driver Wall-Mount D4 Driver 150 (also available in 350 and 700 models) Rack-Mount D4 Driver 350 (also available in 700 model) Note: Antenna is not present on RDM models.
  • Page 4 D1 & D2 Series Drivers Note: All ArcSystem wireless luminaires require a TX1 Transmitter and commissioning tool to set DMX addresses for both wired DMX and wireless installations. Contact your ETC Service Technician for more information. TX1 Transmitter The TX1 Transmitter is the DMX wireless gateway for the ArcMesh protocol.
  • Page 5 ETC Installation Guide D1 & D2 Series Drivers Note: By default the TX1 DMX output is disabled. If you require DMX output from the TX1, you must use the ArcSystem comissioning tool software to add DMX fixtures. ArcMesh Specifications Use up to 100 devices per TX1 transmitter.
  • Page 6: Typical Installation

    ETC Installation Guide D1 & D2 Series Drivers Note: Installation must follow all national and local codes for electrical equipment. Note: Normal and emergency wiring cannot be contained in the same conduit according to NEC 700.10(B). Emergency drivers and luminaires require two branch circuit connections. These inputs have the following functions: 1.
  • Page 7: Before You Begin Installation

    ETC Installation Guide D1 & D2 Series Drivers Installation with DMX Bypass Controller ArcSystem Pro D1, D1 HO, and D2 Series emergency drivers and ArcSystem multi-cell emergency luminaires that are installed in a system with a DMX bypass controller can have their Maintained and Sense inputs fed from an emergency lighting transfer switch (UL1008 ATS).
  • Page 8: Installation Requirements

    ETC Installation Guide D1 & D2 Series Drivers Site Survey for Wireless Installations ArcSystem transmitters and luminaires operate in the unlicensed 2.4 GHz band using the IEEE 802.15.4 standard. This band is shared with other technologies such as Wi-Fi, Bluetooth, low power sensor networks, wireless AV transmitters and some radio microphones.
  • Page 9 ETC Installation Guide D1 & D2 Series Drivers Pro One-Cell Pro One-Cell Pro One-Cell Small fixed model adjustable model adjustable model A Outer bezel B Inner bezel Pro One-Cell High Output Pro One-Cell Micro adjustable model adjustable model Installation Spacing - High Output Luminaires If you are installing ArcSystem Pro One-Cell High Output luminaires, plan the luminaire and driver locations around the required spacing listed below.
  • Page 10 ETC Installation Guide D1 & D2 Series Drivers Installing One-Cell Recessed Luminaires The installation procedure is similar for all recessed one-cell luminaires (fixed and adjustable). For Installing One-Cell Yoke-Mounted Pro One-Cell yoke-mounted luminaires, continue on to Luminaires on the facing page...
  • Page 11 ETC Installation Guide D1 & D2 Series Drivers Installing One-Cell Yoke-Mounted Luminaires 1. Attach a C-clamp or other mounting hardware (not provided) to the yoke of the luminaire. 2. Attach the luminaire to a pipe or other approved mounting device.
  • Page 12 Install the driver on a power distribution system with reliably identified earthed neutral (ground) and install a maximum 20 A circuit breaker on the line conductor. The D1and D2 Series drivers accept 100–277 VAC, 50/60 Hz. ETC recommends installing all wiring in grounded metal conduit. WARNING: Circuits that are installed without an accessible power disconnect device cannot be serviced or operated safely.
  • Page 13 ETC Installation Guide D1 & D2 Series Drivers Wire the Driver Wiring of the driver consists of wiring power and data (DMX) to the driver for your luminaire and then running power out to the luminaire from the driver. If you are installing emergency system drivers, see Emergency System One-Cell Installation on page 16...
  • Page 14 ETC Installation Guide D1 & D2 Series Drivers Power Internal wire colors vary by model. Factory Wire Colors Model Color Type North America ground/earth green/yellow and Europe North America black line/hot North America white neutral Europe brown live Europe blue neutral Perform the following steps to wire power to the driver.
  • Page 15 ArcSystem multi-cell luminaires and standalone drivers are not self-terminating. You must terminate the last multi-cell luminaire or standalone driver in line with a 120 Ω resistor. To purchase an RJ45 terminator, please contact your ETC customer service representative and request part number N4086. D1 & D2 Series Drivers...
  • Page 16 Depending on your installation, you might want to surface-mount the driver. Any ArcSystem standalone driver can be surface-mounted to any surface capable of supporting its weight using the four holes located on the back side of the enclosure. Contact ETC for custom mounting bracket options.
  • Page 17 ETC Installation Guide D1 & D2 Series Drivers Wiring D1 and D2 Series Emergency Drivers D1 Emergency Driver D1 HO Emergency Driver D2 Emergency Driver D1 & D2 Series Drivers Page 17 of 25...
  • Page 18: Complete Installation

    ETC Installation Guide D1 & D2 Series Drivers Note: If you are installing a D1 High Output driver, the power supply is inside the cover and has wiring that runs to the driver board in the back panel of the driver. Be careful when handling.
  • Page 19: Front Panel Leds

    LED on the front panel labeled "MASTER Tx". See Front Panel LEDs above Setup of dual redundancy is done at the time of system commissioning by an ETC certified technician. For more information on this process, contact ETC Technical Services.
  • Page 20: Power Up Procedure

    Programming groups and presets is done through the configuration tool at time of system commissioning. This programming will be done by an ETC certified technician. For more information Commissioning a Wireless ArcSystem on page 23 Both wired and wireless products can be used within a single system.
  • Page 21 ETC Installation Guide D1 & D2 Series Drivers ArcSystem wireless luminaires ARC-TX1 DMX512 DMX512 DMX512 from lighting console ArcSystem wired DMX luminaires Third party DMX devices Note: By default the TX1 DMX output is disabled. If you require DMX output from the TX1, you must use the ArcSystem comissioning tool software to add DMX fixtures.
  • Page 22 ETC Installation Guide D1 & D2 Series Drivers Parameter RDM PID Value Notes DMX Start Address 0x00F0 Range = 001 to 512 Default is 001. Default is 2.This parameter doesn't affect D1 and DMX Personality 0x00E0 1 or 2 D2 Series Drivers. 0 for stop identify, 1 for start...
  • Page 23: Maintenance

    Initial programming of a wireless ArcSystem requires a USB commissioning tool (ARC-CT), and existing hardware such as a laptop or desk top computer that is connected to ArcSystem. This programming will be carried out by an ETC certified technician at the time of system commissioning and training.
  • Page 24 être remplacées seulement par un technicien qualifié. Contactez le service client ETC pour obtenir de l’assistance. WARNING: Disconnect the fixture from power and DMX and allow it to cool before performing any cleaning and maintenance.
  • Page 25: Fcc Compliance

    ETC Installation Guide D1 & D2 Series Drivers CAUTION: This equipment has more than one power supply connection point. To reduce the risk of electric shock, disconnect both the branch circuit-breakers or fuses and emergency power supplies before servicing. ATTENTION : Cet équipement possède plusieurs points de connexion...