Data I/O PSV5000 Owner's Manual page 20

Hide thumbs Also See for PSV5000:
Table of Contents

Advertisement

Introduction ■ System Description
Devices in the programming sockets undergo any or all of the following
processes as determined by the job. These processes are set in TaskLink:
(Optional) Mark devices—
When available, devices that pass the programming and verification
operations are marked at the Laser Module for identification.
3.
Devices are moved by the PNP head to output media: trays, tubes, or
tape. Devices that fail one of the programming processes are placed into
the reject bin or reject tray.
Input and Output Options
PSV5000 System input and output options are: static tray (manual), tray
feeder (automatic), tube, and tape.
Most combinations of input and output options may be used. For
example, the PSV5000 System can be configured with input as static
tray and output as taped.
Manuals for Optional Equipment
The manuals that came with any optional equipment on your system
contain additional, more in-depth information. Some of the manuals
came in hard copy format with your PSV5000 System. Others are PDFs
installed on the Handler computer.
- 16 -
Continuity check
ID check
Erase
Blank check
Program
Verify programming
Read
Illegal-bit check
Functional verification operations
Secure device
Verify options such as voltage
Load devices into the output media—
Data I/O ■ 096-0465-001C