Using The Command And Response Table; Common Symbol Definitions - Extron electronics FOX3 T 201 User Manual

Fiber optic hdmi transmitter
Hide thumbs Also See for FOX3 T 201:
Table of Contents

Advertisement

Using the Command and Response Table

The command and response table begins below. Symbols are used throughout the table
to represent variables in the command and response fields. Command and response
examples are shown throughout the table. The ASCII to HEX conversion table below is for
use with the command and response table.
Space
NOTE: For commands and examples of computer or device responses used in this
guide, the character "0" is the number zero and "O" is the capital letter "o."

Common symbol definitions

]
= Carriage return/line feed
= Space
} or
= Carriage return (no line feed)
|
E
or W = Escape key
X!
= Video mute
X@
= Audio output
X#
= Audio mute status
X$
= Input video signal status
X%
= Input audio status
X^
= Input HDCP status
(default)
X&
= Output HDCP status
X*
= Input audio selected
X(
= Device type
X1)
= Enable DHCP
X1!
= IP address, subnet,
gateway address
X1@
= Baud rate
X1#
= Parity
X1$
= Data bits
X1%
= Stop bits
X1^
= UARTs
ASCII to Hex Conversion Table
0 = Unmute (default) 1 = Mute video only
2 = Mute video and sync
1 = Digital (Tx Loop Out)
2 = Analog
3 = All outputs (digital and analog)
0 = Unmute (default), 1 = Mute
0 = Not detected, 1 = Detected
0 = Not detected, 1 = Detected
0 = No source detected
2 = Source with no HDCP present
0 = No active sink detected
1 = Sink detected, output encrypted
2 = Sink detected, output not encrypted
0 = Auto
TX or RX
0 = Off (default) 1 = On
xxx.xxx.xxx.xxx
300 − 115200 baud (9600 default)
odd, even, none (default), mark, space
(only the first letter required)
7, 8 (default)
1 (default), 2
1 = Endpoint
FOX3 T 201 Transmitter • SIS Configuration and Control
1 = Source with HDCP detected
1 = Digital
2 = Analog
20

Advertisement

Table of Contents
loading

Table of Contents