Establishing A Connection - Extron electronics FOX3 T 201 User Manual

Fiber optic hdmi transmitter
Hide thumbs Also See for FOX3 T 201:
Table of Contents

Advertisement

Default IP address
To access the FOX3 transmitter via the LAN port, the IP address, subnet mask, and the
gateway address for the devices are needed. If the addresses have not been changed, the
factory‑specified defaults are:
IP address
Gateway address 0.0.0.0
Subnet mask

Establishing a Connection

Establish a network connection to a FOX3 device as follows:
1.
Download the SSH client software from the internet.
2.
Open the SSH client software.
3.
Enter the IP address of the FOX3 device in the Host Name or IP address field.
NOTE: If the local system administrators have not changed the value, the default IP
address is 192.168.254.254.
4.
Enter 22023 in the Port field.
5.
The FOX3 device is password protected, so the appropriate administrator or user name
and password must be entered.
If the login and password are correct, the device responds with a copyright
message including the copyright year, the name of the product, firmware version,
part number, and the current date and time.
If the login and password are incorrect, the Login as prompt returns. Enter the
administrator or user name and password again.
NOTES:
Using verbose mode
SSH connections to a FOX3 device can be used to monitor for changes that occur on
the device, such as SIS commands from other SSH sockets or a serial port. For an SSH
session to receive change notices from the device, the SSH session must be in verbose
mode 1 or 3 (see the SIS command
192.168.254.254
255.255.255.0
The FOX3 device is shipped password‑protected. The factory configured
passwords for all accounts on this device have been set to the device serial
number.
In the event of a complete system reset, the password converts to the default,
which is extron. New passwords must be configured to secure the device.
On password‑protected connections, there are two levels of protection:
administrator and user. Administrators have full access to all editing functions.
Verbose mode
FOX3 T 201 Transmitter • SIS Configuration and Control
on page 23).
18