Using the Command and Response Table

The
throughout the table to represent variables in the command and response fields. Command
and response examples are shown throughout the table. The SIS commands are not
case sensitive. The ASCII to HEX conversion table below is for use with the command and
response table.
Space
Symbol definitions
]
= Carriage return/line feed
}
= Carriage return (no line feed)
|
= Pipe (can be used interchangeably with the
= space
E
= Escape key
W
= Can be used interchangeably with the
X!
= Input number
X@
= Switch mode
NOTE: Auto-input switch low (
X#
= Status
X$
= HDMI input
X%
= Input HDCP status
X^
= Output HDCP status
X&
= EDID
X*
= User EDID location
X(
= Raw EDID data
X1)
= Resolution and rate in plain text
X1@
= Switch position
X1#
= Switcher name
X1$
= Embed audio
NOTE: VGA input only has option 0 and 1 for
X1%
= Tally pin mode when channel is muted
X1^
= Firmware version number to second decimal place (x.xx)
X1&
= Verbose mode
command and response table
ASCII to Hex Conversion Table
}
character)
E
character
or
through
0
1
assignment)
= Manual (default)
0
= Auto-input switching high
1
X@
=
2
) is not available from the front panel.
0
= Off, disabled, or not detected
or
2
3
0
= No source is detected
= Source is detected with HDCP
1
0
= No sink is detected
= Sink is detected with HDCP
1
See the
table
,
, or
66
67
68
128 or 256 bytes of hexadecimal data
Example:
1920x1200
= DTP
0
A text string of up to 24 alphanumeric characters and minus sign/hyphen (-).
No blank or space characters are permitted as part of a name. The first character must
be a letter, and the last character must not be a minus sign/hyphen.
= Embedded digital audio
0
1
= Analog audio input
X1$
.
= Always on (default)
0
= Off when muted
1
0 = Clear/none
1 = Verbose mode (default)
begins on the next page. Symbols are used
(
= no input for switching command or always output for audio
3
0
= Auto-input switching low
2
1
= On, enable, or detected
2
= Source detected without HDCP
2
= Sink is detected without HDCP
on page 20.
@60Hz
= HDBT
1
= Auto select (Digital takes priority) (default)
2
= Blink when muted
2
2 = Tagged responses for queries
3 = Verbose mode and tagged for queries
DTP T USW 233 • Remote Control