controller's operation. Amounts of air for
given burner power are set in the menu:
Boiler settings → Output modulation
Description of remaining parameters relaed
to Lambda sensor:
Prameter
Blow-in
permissible scope of variability of airflow
power
by
work
Parameters Dynamics and Reaction time
have influence on regulation time of air
amount in fumes to preset amount and on
stability
of
air
in
recommended to change these parameters if
regulation time and stability of keeping
preset amount of air on required level.
Periodical
calibration
readings can
be
Lambda sensor calibration it is necessary to
extinguish the boiler. To make a successful
calibration the furnace in boiler must be
completely extinguished. To start up the
calibration use the parameter in the menu:
Boiler settings → Lambda calibration
Calibration process lasts approximately 8
minutes.

18 Software update

Simultaneous update of the regulator and
panel software can be done using memory
card only type microSDHC.
Software
performed only by a qualified
person. Precautions to prevent
electrocution should be observed.
To update the software disconnect power
supply of the regulator. Insert memory card
(other types of memory cards are not
supported) to a socket in the movable casing
of the panel shown above. On the memory
card there should be written new software in
the *.pfc format as a 2 files: a file with the
panel software and a file with the module A
software.
output
scope
using
lambda
sensor.
fumes.
It
is
of
Lambda
sensor
necessary. To
conduct
update
can
sets
not
Software files should be placed directly on
the memory card, do not place them in any
be
subdirectory, then connect power supply of
the regulator and go to the menu: General
settings → Software update and perform
the update firstly in the main module, then in
the control panel and in the end in other
devices.

19 The regulator configuration by boiler

producer

The producer of boiler / burner should adjust
program parameters in controller to given
type and power of the burner. The most
important parameters are those related to
Firing up, Operation and Burning off. The
regulator is able to change the default
settings depending on power and type of the
burner. Default settings for given boilers /
burners should be consulted with Company
Plum Sp. z o. o. In order to load new
parameters go to:
43