17 Lambda sensor

Burner
efficiency
connecting
additional
module. Connect the module according to
electric scheme. Lambda sensor is to be
activated in:
Service settings → Burner settings →
Lambda sensor
If parameter Operation with Lambda sensor
is set on ON then the controller will operate
using Lambda sensor readings. The amount
of air provided to the furnace will be
automatically set in such a way to obtain
preset amount of air in fumes. If this
parameter is set on OFF then Lambda sensor
readings
will
not
controller's operation. Amounts of air for
given burner power are set in:
Boiler settings → Output modulation
Periodical
calibration
readings can
be
Lambda sensor calibration it is necessary to
extinguish the boiler. To make a successful
calibration the furnace in boiler must be
completely extinguished. To start up the
calibration use the parameter:
Boiler settings → Lambda calibration
Calibration process lasts approximately 8
minutes.

18 Software update

Simultaneous update of the regulator and
panel software can be done using memory
card only type microSDHC.
Software
performed only by a qualified
person. Precautions to prevent
electrocution should be observed!.
can
be
increased
Lambda
sensor
have
influence
of
Lambda
sensor
necessary. To
conduct
update
can
by
on
To update the software:
disconnect power supply of the regulator.
insert microSDHC memory card (other
types
supported) to a socket in the movable
casing of the panel shown above. On the
memory card there should be written new
software in the *.pfc format as a 2 files:
a file with the panel software and a file
with the module A software.
Software files should be placed directly
on the memory card, do not place them
in any subdirectory,
then
connect
regulator and go to:
General settings → Software update and
be
perform the update firstly in the A module,
then in the panel, and in the end in other
devices.
Registry changes:
43
of
memory
cards
power
supply
are
not
of
the