Scheme with heat buffer
temperature sensor, 5 – exhaust temperature sensor, 6 – boiler pump, 7 – heating buffer, 8 – HUW pump, 9
- mixer valve actuator, 10 – mixer temperature sensor, 11 – mixer pump, 12 – upper buffer temperature
sensor, 13 – lower buffer temperature sensor, 14 – standard room thermostat or ecoSTER TOUCH room
panel, eSTER_x40 room thermostat, 15 – thermostatic 3-way valve for return protection, 16 – outside
temperature sensor (weather), 17 – thermostat to turn off the pump, 18 - additional module B.
RECOMMENDED SETTINGS:
Parameter
Preset boiler temperature
Minimum boiler temperature
CH pump activation temperature
Buffer support
Buffor loading start temperature
Buffor loading end temperature
Mixer 1 support
Max. mixer 1 temp.
Mixer 1 heating curve
Mixer 1 weather control
Thermostat select.*
Mixer 2 support
Max. mixer 2 temp.
Mixer 2 heating curve
Mixer 2 weather control
Thermostat select.*
* when a standard room thermostat with ON-OFF contacts is connected instead of the room panel, select the
option for the thermostat=Universal or, if the setting is hidden, do not need to select any option for the
thermostat.
3
The presented hydraulic diagram does not replace central heating engineering design and may be used for
information purposes only!
3
: 1 – boiler, 2 – control panel in the separated version, 3 –regulator, 4 – boiler
Setting
80C
75C
55C
ON
50C
75C
CH ON
70C
0.8 – 1.4
ON
ecoSTER T1
Floor on
45C
0.3 – 0.8
ON
ecoSTER T1
eSTER T1
Boiler settings
Service settings Boiler settings
Service settings CH and HUW settings
Service settings Buffer settings
Service settings Buffer settings
Service settings Buffer settings
Service settings Mixer 1 settings
Service settings Mixer 1 settings
Mixer 1 settings
Mixer 1 settings
Service settings Mixer 1 settings
Service settings Mixer 2 settings
Service settings Mixer 2 settings
Mixer 2 settings
Mixer 2 settings
Service settings Mixer 2 settings
22
18
MENU