No Communication; No Supply; Unsuccessful Boiler Firing - Up Attempt; Firmware Update - Plum ecoMAX920P1-S TOUCH Installation And Operating Manual

Controller for automatic solid fuel fired boilers
Table of Contents

Advertisement

15.7

No communication

The control panel is connected with executive
module via RS485 cable. In case of cable
damage
the
alarm
controller does not switch off the regulation
and
operates
normally
programmed parameters.
Check the cable connecting control panel
with the module and replace or repair it if
necessary.
15.8

No supply

In case of no supply the controller will return
to operation mode in which it operated
before power failure.
15.9
Unsuccessful
attempt
The alarm will
occur
attempt of automatic boiler furnace firing-up.
After the alarm trips all pumps will be off in
order not to cause excessive boiler cooling.
Causes of this alarm can be e.g. damaged
lighter or no fuel in the container.
Alarm is erased by resetting the controller.
16

Firmware update

Simultaneous replacement of firmware in
module and controller's panel can be done
using memory card.
Firmware update can be done
only by an authorized person,
keeping all precautions against
electric shock!.
To replace firmware:
Disconnect controller's electrical supply,
is
displayed.
The
with
previously
boiler
firing-up
after unsuccessful
Insert microSD HC memory card (other
card type is not supported) into indicated
slot, placed in a movable panel housing.
New software should be written on the
card in *.pfc format in the form of two
files: file with panel program and a file
with
program
controller,
Place
new
memory card, do not place data in a
folder,
Then connected electrical supply to the
controller
and
settings → Firmware update – replace
firmware first in main A module of the
controller, next in controller's panel, then
in other devices.

17 Other controller functions

17.1

Power failure

In case of power failure the controller will
return to the mode in which it operated
before power failure.
17.2

Anti-freeze protection

When boiler temperature drops below 5C,
the
boiler
pump
overriding circulation of boiler's water. If
water temperature will not increase, then the
boiler's burner switches on.
This function cannot be the only
protection
freezing! Other methods should be
applied. The controller's producer
is not responsible for damages
related to this.
17.3
Pumps standstill protection
function
The controller performs the CH, HUW pump
and
mixers
standstill. It switches them on periodically
)every 167h for a few seconds). It protects
pumps against immobilization due to boiler
scale build-up. Therefore, during pause in
using boiler, the controller's supply should be
connected. The function is performer also
with controller off (the controller in "Boiler
off" mode).

18 Lambda probe

The burner efficiency can be increased by
connecting additional Lambda probe module.