Power Up The Node; Verify The Operation Of A Replacement Dimm - Dell EMC PowerStore 1000 Installation And Service Manual

Hide thumbs Also See for EMC PowerStore 1000:
Table of Contents

Advertisement

Figure 77. Sliding the node halfway into the chassis
3. Pull the black release tab out completely, and slide the rest of the node back into the chassis.
The black release tab slides back into the system as it is inserted.
Figure 78. Installing the node
4. Pull the orange release trigger and push in gently to re-engage the locking mechanism.
If the black release tab comes out when pulled, the locking mechanism is not engaged.

Power up the node

Power up the node as described in

Verify the operation of a replacement DIMM

Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance where you replaced the DIMM.
3. On the Components card, under Internal View, expand the node that includes the DIMM, and then select the relevant
DIMM.
Power control
procedures.
Base enclosure service procedures
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents